3-5
Setup of Overtravel Limit Switches
and Home Positions
3-5-1

Wiring of Devices

The figures below show how to wire the CK3M to various sensors.
S8VK-S12024
Connect the EE-SX674 to the following FLAG terminals of the CK3W-AX2323N.
• PLIM0: X-axis positive overtravel limit switch
• NLIM0: X-axis negative overtravel limit switch
• PLIM1: Y-axis positive overtravel limit switch
• NLIM1: Y-axis negative overtravel limit switch
The following shows an example of wiring to the HOME0 terminal.
24 V
0 V
Output
3-5-2

Programming

Set up the overtravel limit switches.
Application Guide Laser Application (O052)
S8VK-S12024
EE-SX674
V_FLAG 0
HOME 0