XIP or RXQP on a working GSM 1800 receiver this picture should be seen.
Signal amplitude peak-peak 460 mV
DC offset 1.2 V

Measurement points in the receiver

Figure 37:RX measurements point for the RX/TX Switch - Z700
42
Figure 36:RX1800 I/Q signal waveform