CCS Technical Documentation
Reference
Name
number
N601
Mjoelner RF ASIC
B601
26 MHz Xtal
Z602
GSM1800 RX SAW
Z603
GSM1900 RX SAW
Z604
EGSM RX SAW filter
Z701
EGSM TX SAW filter
T701
GSM1800/GSM1900 TX Balun
V802
EGSM Pre-amplifier
G701
3.7 GHz VCO
T702
VCO Balun

RF Measurement points

RF Supply points
RF power supplies are generated in the UEM and can be measured either in the Mjoelner
can or in the baseband can. Arrows mark the measurement points inside the pictures.
Issue 1 09/2003
Company Confidential
Figure 2: RF Supply points inside Mjoelner can
Copyright  2003 Nokia Corporation
Company Confidential
RF Troubleshooting
Reference
Name
number
X602
RF Connector
L801
Directional Coupler
V801
Detector Diode
Z601
Antenna switch
N801
Power Amplifier
NEM-4