Fig 24 Rx I/Q Signals, Baseband Shielding Can Uem (D200) - Nokia RH-59 Troubleshooting Instructions

Table of Contents

Advertisement

Nokia Customer Care
By measuring with an oscilloscope at RXIP or RXQP on a working GSM 1900 receiver this pic-
ture should be seen.
Signal amplitude peak-peak 460 mV
DC offset 1.2 V
28
Figure 21: RX1900 I/Q signal waveform
COMPANY CONFIDENTIAL
Copyright © 2004 Nokia. All Rights Reserved.
RH-59/60
ISSUE 1 09/2004