RH-59/60
By measuring with an oscilloscope at RXIP or RXQP on a working GSM 850 receiver this pic-
ture should be seen.
Signal amplitude peak-peak 789 mV
DC offset 1.2 V
ISSUE 1 09/2004
Figure 18:RX850 I/Q signal waveform
COMPANY CONFIDENTIAL
Copyright © 2004 Nokia. All Rights Reserved.
Nokia Customer Care