Nokia Customer Care
2 Enter the loss values for the RX Low, Mid and High channels on both bands.
3 If the jig "DA-17" is not defined yet, you must generate it by clicking the Add
button. Assign it the name DA-17.
4 Click Save.
Assigning the product to the jig
To make the calibration data valid, it is necessary to assign the DA-17 jig to the product
"RH-47".
Procedure:
1 Click the Product tab.
2 Enter "RH-47" into the Product column.
3 From the "Used Jig" dropdown menu, choose DA-17.
4 First click Save and then Close.
You are ready for Autotuning.
GPIB Setup for Autotuning
Prerequisites:
• GPIB card on Phoenix PC must be installed and working.
Issue 1 05/04
Company Confidential
7 - RF Description and Troubleshooting
Copyright © 2004 Nokia Corporation
Company Confidential
RH-47
Page 73