Appendix B: Finui Test Cases With Hints For Repair - Nokia RH-47 Series Rf Description And Troubleshooting

Hide thumbs Also See for RH-47 Series:
Table of Contents

Advertisement

RH-47
7 - RF Description and Troubleshooting

APPENDIX B: FINUI Test Cases with Hints for Repair

testplan aquarius_440 (FinUI)
Step Nr.
Sequence Name
1
MainSequence
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
Page 50
Company Confidential
Table 2:
Step Name
Low Limits
Copyright * 2004
Label
Nokia Mobile
Phones
Keypad_Start_Tes
0
t
Calibration Ini-
PassFailTest
tialize
Check Battery
0
Voltage
Testmode Current
35
Meas
Set Voltage (3V6)
0
Initialize Keithley
PassFailTest
2015
Charge Volt &Curr
-0,6
Charge Volts ADC
57000
Charge Current
3600
ADC
Check Headset
17
Detect
Check Sim Card
PassFailTest
Inserted
Meas Vibra Cur-
45
rent
Check Keypad
1
func
Audio Robot
0
Move To MIC
Measure XEAR-
-6
>MIC @1kHz
Move robot On
-0,5
the Earp
Measure EAR-
-6
>XMIC @1kHz
Move robot Home
-0,5
Copyright © 2004 Nokia Corporation
Company Confidential
Nokia Customer Care
High Limits
Unit
RF Test
10
1023
ADC
150
mA
10
-
-0,1
A
63000
ADC
5000
ADC
17
-
120
mA
1
rpt
10
-
6
0,5
-
6
dB
0,5
-
Repair comment
Issue 1 05/04

Advertisement

Table of Contents
loading