Measuring Rx Performance Using Snr Measurement - Nokia RH-47 Series Rf Description And Troubleshooting

Hide thumbs Also See for RH-47 Series:
Table of Contents

Advertisement

RH-47
7 - RF Description and Troubleshooting
The setup should now look like this:
4 Make the following settings on your signal generator:
Frequencies:
GSM850:
set)
GSM1900:
set)
RF power level:
– 80dBm @ the antenna connector of the phone (remembering to compen-
sate for the cable and jig attenuation).
5 In RSSI reading, click Read now.
The resulting RSSI level should be – 80dBm +/– 0.5dB in each band.

Measuring RX performance using SNR measurement

1 Start Phoenix Service Software and open FBUS connection.
Select
Wait until phone information is shown in the lower right corner of the screen.
2 Set operating mode to local mode.
Page 18
Company Confidential
881.66771 MHz (channel 190 + 67.710kHz off-
1960.06771 MHz(channel 661 + 67.710kHz off-
Scan Product
Copyright © 2004 Nokia Corporation
Company Confidential
Nokia Customer Care
Ctrl-R
Issue 1 05/04

Advertisement