Figure 41 Close All Cma Bracket Clips - Seagate Exos CORVAULT Hardware Installation And Maintenance Manual

Hide thumbs Also See for Exos CORVAULT:
Table of Contents

Advertisement

To route and connect power cords and data cables:
1. Route the power cords straight toward and then behind the first L-shaped bracket.
2. Continue routing and flattening the power cords around the second L-shaped bracket to the far right, then drape
them down the left face of the rear panel. They temporarily cover the first system fan, awaiting power connection.
3. Open the CMA bracket assembly clips, each embossed with King Slide on the top.
4. Holding the CMA bracket assembly away from the chassis, route the data cables from the CMA cable capture arm
through the first two CMA L-shaped bracket clips.
5. Make sure the data cables lie as flat as possible and fit best in the space.
6. Release the CMA bracket assembly, then continue to route data cables beyond the bend and through the next four
CMA bracket clips.
7. Keep cables as flat as possible, so that all data cables meet the bend radius for that cable type.
8. Gently snap closed all bracket clips around the routed data cables.

Figure 41 Close all CMA bracket clips

9. Take the following actions to connect the routed data cables to the appropriate server's host bus adapter (HBA) or
appropriate management network switch:
a. Connect the data cables numbered 1 and 2 to the top two ports in one HBA.
b. Connect the data cables numbered 3 and 4 to the lower two ports in a second HBA.
c. Connect the data cables numbered 5 and 6 to the available top two ports in the second HBA.
d. Connect the data cables numbered 7 and 8 to the available lower two ports the first HBA.
46            Chapter 4   Route power cords and data cables