6. Proceed to next crosstalked inverter and repeat the
procedure.

Installer Configuration Tool

The Installer Configuration Tool allows configuration and
provisioning of Generac PWRcell systems from a smart-
phone or laptop. The interface allows installers to config-
ure basic settings, set inverter compliance, generate a
compliance report, and understand system performance.
The interface is only available on Generac PWRcell sys-
tems with a REbus Beacon installed. Close proximity to
the Beacon is required for use. It is not possible to
access this tool remotely. 45 minutes after being acti-
vated, the Beacon's WIFI signal will time out and may
need to be reactivated. For Beacon installation instruc-
tions, see
REbus Beacon
NOTE: All PWRcell inverters come with a REbus
Beacon pre-installed.
Accessing the Installer Configuration Tool
1. Navigate to the Beacon device page on the PWR-
cell inverter control screen and press the center
button.
2. Select Installer Tool from the menu and click Con-
firm. This will activate the Beacon's Wi-Fi network.
3. Use a smartphone or laptop to connect to the Wi-Fi
network SSID titled: REbus_Beacon_xxxx where
xxxx is the last 4 digits of the Beacon's RCP num-
ber.
NOTE: The Beacon's RCP number can be found on the
front of the Beacon located inside the inverter, as well as
on the Beacon device page through the inverter's screen.
To find this number through the inverter's screen press
the center button on the Beacon device page. The RCP
number will be displayed at the bottom of the menu
screen.
4. Type in the password (labeled "CODE") for the
REbus Beacon's Wi-Fi network.
NOTE: The code for the REbus Beacon's Wi-Fi network
is located on the back of the Beacon inside of the
inverter. The Beacon is mounted on the upper left-hand
sidewall of the inverter housing. Unstick the Beacon to
view the code labeled on the back.
NOTE: Where utility requirements contain provisions for
security against adjusting compliance settings, consider
removing code label for the Beacon after successful
commissioning.
5. See
6-29. Open a web browser on a smart-
Figure
phone or laptop and enter 10.10.10.10 for the
Installation Manual for Generac PWRCell Inverter
Setup.
browser URL. The installer tool will appear in the
browser.
Figure 6-29. Installer Configuration Tool
Configuring Basic PWRcell Settings
NOTE: To customize basic settings, the inverter must be
disabled. Before disabling the inverter, ensure all REbus
devices have first been disabled. Settings changes will
not be applied if the inverter is enabled.
1. Select Inverter from the Beacon menu.
NOTE: If using a smartphone, open the menu by click-
ing the hamburger icon in the upper-right corner of the
screen. Laptop users will see the menu displayed on the
left side of the screen.
2. Select PWRcell Configuration.
Commissioning and Setup