Table 9-3: Further troubleshooting
Description of fault
No reading on the display
Actuator moves too slowly
Actuator moves in the wrong direction.
Air leaks from the positioner.
9.1.1
Clearing error codes
The E0 and E3 to E8 error codes can be cleared as follows:
EB 8484-1 EN
3. Turn
to select the error code.
4. Press
, ESC is displayed. The error code blinks.
5. Turn
until RST appears.
6. Press
to clear the error.
Î The reset procedure can be canceled by pressing rotary pushbut-
ton while ESC is displayed.
Measures
Î Check electrical connection and power sup-
ply.
Î Check the supply pressure.
Î Check the cross-section of the piping and
screw fittings.
Î Check the configuration of the mounting
parts.
Î Check the direction of action (Code P8).
Î Check the characteristic setting.
Î Check piping.
Î Check the configuration of the mounting
parts.
Î Check seals.
Malfunctions