Lenovo ThinkSystem SR250 Messages And Codes Reference page 89

Hide thumbs Also See for ThinkSystem SR250:
Table of Contents

Advertisement

User Action:
Information only; no action is required.
• FQXSPPU2011I: An SM BIOS Uncorrectable CPU complex error for [ProcessorElementName] has
deasserted.
This message is for the use case when an SM BIOS Uncorrectable CPU complex error has deasserted.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - CPU
SNMP Trap ID: 40
CIM Prefix: PLAT CIM ID: 0817
User Action:
Information only; no action is required.
• FQXSPPW0001I: [PowerSupplyElementName] has been added to container
[PhysicalPackageElementName].
This message is for the use case when an implementation has detected a Power Supply has been added.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0084
User Action:
information only; no action is required.
• FQXSPPW0002L: [PowerSupplyElementName] has Failed.
This message is for the use case when an implementation has detected a Power Supply has failed.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Power
SNMP Trap ID: 4
CIM Prefix: PLAT CIM ID: 0086
User Action:
Complete the following steps:
1. Please ensure the PSU wattage, PSU efficiency level and the power supply unit is supported for the
system.
2. Check power supply LEDs:
a. If AC LED is not lit, check power cord and input voltage. once the problem still exist, then replace
the power supply.
b. If power supply model is no AC LED, then please power off the system then reseat PSU and
reboot system
c. If problem still exist, please send system event log to service for further investigation.
• FQXSPPW0003G: Failure predicted on [PowerSupplyElementName].
.