Prior to set up

Floor bearing capacity
Ensure that the substructure is capable of bearing the weight of the
stove prior to set-up.
Note
No modifications may be made to the firing installation. This also
leads to loss of warranty and guarantee.
Floor protection
A glass, sheet steel or ceramic plate is required, if the floor is
combustible (wood, carpet, etc.).
Flue pipe connection
Flue pipes pose a particular source of hazard regarding gas leaks
Q
and fire. Get the advice of an authorised specialist company for
the layout and assembly.
Please observe the corresponding installation guidelines for walls
Q
panelled with wood when connecting your flue pipes to the stove,
Observe the formation of flue gas (atmospheric inversion) and
Q
draughts when the weather is unfavourable.
Infeed of too little combustion air can lead to smoke in the rooms
Q
or to flue gas leaks. Hazardous deposits in the stove and chimney
may also occur.
If flue gas escapes, let the fire burn out and check whether all the
Q
air inlet openings are free and the flue gas pipes and the stove
pipe are clean. If in doubt notify the master chimney sweep since
draught malfunctions may be connected to your chimney.
Convection air conduction
only for stoves with MultiAir
The MultiAir equipped stove is delivered with a cover on the
convection air outlet to prevent direct heat to the wall.
Operation without this cover or without attached convection pipes is
not allowed. If you do though no warranty and no liability is accepted
for damage.
The amount of air and temperature of one fan is designed to heat
Q
one additional room.
Note the regional specific fire safety regulations and clarify the
Q
connection situation with the competent authority
The max. temperature of the convection air is 180 °C at the air
Q
outlet.
The convection air canal should be as short as possible.
Q
Keep the number of deflections as small as possible.
Q
Note
Please pay attention to the national and country-specific building
and fire regulations when connecting the convection air pipes.
Installation and assembly must be performed by a trained
specialist only.
Stoves type 1 (BA 1):
These may only be operated with the combustion chamber door
Q
closed.
Suitable for multiple occupancy. (note the different country
Q
regulations)
The combustion chamber door may only be opened to add fuel
Q
and must then be closed again otherwise other firing installations
connected to the chimney may be endangered.
The combustion chamber door is to be kept closed when the
Q
stove is not in operation.
Fouling of the chimney i.e. deposits of highly inflammable materials
Q
such as soot and tar and subsequently fire in the chimney may
occur if the chimney is miscalculated and dimensioned wrong
and if wet wood is used.
If fire in the chimney occurs, disconnect the mains plug of the stove.
Phone the fire brigade and get yourself and other residents out of
harm's
Note
Due to the size of the combustion chamber door it is necessary
not to open the door abruptly, to prevent the flames coming out.
Especially when reheating into blazing flames.
Note
on ROOM-AIR DEPENDENT and
ROOM-AIR INDEPENDENT OPERATION:
Your stove has been tested as a room-air independent stove
according to EN13240 and to EN14785 and can be installed as well
room-air dependent and independent. In Germany it does not
conform to the requirements for room-air independent operation.
When installed room-air dependent in combination with room-
air installations (e.g. controlled ventilation and venting systems
(extractors etc.) it must be ensured that the stove and the room
air system are monitored and safeguarded mutually (e.g. via a
differential pressure controller etc.).
The combustion air infeed of approx. 20 m
Please observe the respective local regulations and rules in
consultation with your master chimney sweep. For changes after
the printing of this manual, we can not assume any liability. We
reserve the right to change without notice.