Introduction

ATS1170 is a low cost, compact remote arming station. ATS1170 performs all
necessary functions to control the operation of a single door. It will operate online
in a control panel system or as a stand-alone device with only an external 12 V
DC supply. Even a combination of both is possible: normally online and offline if
communication to the control panel is interrupted.
ATS1170 can be programmed to operate with one Wiegand or one magnetic
stripe card reader together with a simple Request to Exit push. ATS1170 can
hold up to 15 user card numbers. For offline programming DIP switch A must be
on — see "Basic setup and programming for offline access control" on page 8 for
offline programming.

ATS1170 menus

1 Off line Unlock Time
2 Request to exit Control
3 Display Dipsw C (Card Format)
4 Display Dipsw B (Card Type)
5 LED 1 Options
6 LED 2 Options
7 Reserved
8 Factory Defaults
9 Version Number
10 Learn Mode
11 Number of Cards
12 Last Card Code
13 Delete Card

Basic setup and programming for online access control

Note:
In online programming mode, DIP switch A will have no effect. However,
always leave it in the Off position. This switch is only used in the offline mode to
program cards. See "Basic setup and programming for offline access control" on
page 8 for details.
Setting the address of ATS1170
Using the DIP switch address (nearest the connector strip) select the required
RAS address for this ATS1170. See the ATS1170 installation sheet for available
RAS addresses.
Polling ATS1170
Go to control panel installer menu 3–Poll RAS. Enter the RAS address according
to the DIP switch address selected previously.