Filling The Container - Stihl SR 200 Instruction Manual

Hide thumbs Also See for SR 200:
Table of Contents

Advertisement

English
Machines without pressure pump
Set the "standard" metering knob to
N
6.
Start the machine.
N
Hold the spray tube horizontally, run
N
the engine at full throttle, spray the
contents of the container down to
the 5 liter mark and note the time
taken.
The time required to spray 5 liters fluid
should be between 110 and
150 seconds.
Machines with pressure pump (special
accessory)
Fit metering knob 2.0 in the nozzle.
N
Start the machine.
N
Hold the spray tube horizontally, run
N
the engine at full throttle, spray the
contents of the container down to
the 5 liter mark and note the time
taken.
The time required to spray 5 liters fluid
should be between 100 and
130 seconds.
In case of deviations:
Check the container, hose system,
N
metering knob and optional
pressure pump for contamination
and clean if necessary.
Check blower air intake and clean if
N
necessary.
Check engine setting and correct if
N
necessary.
If there is no improvement, contact your
dealer for assistance.
18

Filling the Container

Turn the cap counterclockwise until
N
it can be removed from the
container opening.
1
The gasket (1) in the cap must be in
N
good condition and clean.
Stand the machine on a level
N
surface.
Close valve lever (1) for solution
N
feed.
Pour thoroughly mixed spray
N
solution into the container through
the strainer.
Do not exceed maximum fluid level of
10 liters (2.6 US.gals).
1
Fit the cap and turn it clockwise with
N
both hands – tighten it as firmly as
possible.
10L
5L
SR 200