Introductory information
Your system is preset
Frost protection
Your heat generator and DHW cylinder (if installed)
are protected against frost.
The frost protection function is only possible when an
outside temperature sensor is connected. Frost pro-
tection function is active at outside temperatures
below 5 °C. The burner is switched on and the boiler
water temperature is held at 20 °C.
Wintertime/summertime changeover
This changeover is automatic.

Energy saving tips

Saving energy when using central heating
Do not overheat your home. Every degree of room
temperature reduction saves up to 6 % on your heat-
ing bills.
Weather-compensated operation and room tempera-
ture-dependent operation:
Never set your standard room temperature (standard
temperature level "n2") higher than 20 °C.
Heat your home to the reduced temperature at night
or during regular absences:
Weather-compensated operation:
Reduced room temperature
Continuous operation and room temperature-
dependent operation:
Reduced flow temperature
In constant operation, adjust the time program for
central heating; see page 18.
In room temperature-dependent operation, time pro-
grams for central heating can only be adjusted at the
room temperature controller or OpenTherm control-
ler.
Operating instructions for the room tempera-
ture controller or OpenTherm controller

Tips for greater comfort

More comfort in your home
Set your individual preferred temperature: See
page 20.
Adjust the time program for your heating circuits so
that your individual preferred temperature is auto-
matically reached when you are present: See
page 18.
In room temperature-dependent operation, time pro-
grams for central heating can only be adjusted at the
room temperature controller or OpenTherm control-
ler. See the operating instructions for the controller.
Only for weather-compensated operation:
Adjust the heating curves so that your home is
heated with your individual preferred temperature all
year round: See page 20.
12
(cont.)
Date and time
The date and time were set by your heating contrac-
tor.
You can change the settings at any time to suit your
individual requirements: See page 24.
Power failure
All settings are saved if there is a power failure.
Saving energy on DHW heating
At night or during regular absences, heat the DHW to a
lower temperature. To do so, adjust the time program
for DHW heating: See page 19.
For additional energy saving functions, please contact
your contractor.
Sufficient DHW heating for your needs
Adjust the time program for DHW heating so that there
is always sufficient hot water in accordance with your
habitual routines: See page 19.
Example: You need more DHW in the morning than in
the daytime.