PREPARE THE HOOD

3
Remove
Damper/Duct
Connector from
inside the hood.
Set connec-
tor aside - with
mounting screws
and parts bag.
DAMPER/DUCT
CONNECTOR
Remove Wir-
4
ing Cover from
inside the hood.
Set cover and
mounting screw
aside.
WIRING
COVER
5
Remove either
top or back wir-
ing knockout and
install approved
Electrical Cable
Clamp.
ELECTRICAL CABLE CLAMP
Non-Ducted Installation - Skip to "Connect
Wiring" section.
The following
Steps (6 thru
13) are for
DUCTED
INSTALLATION
ONLY.
6
Remove Light Panel - held in place with (3) #8 screws
and (2) #8 screws. Disconnect light assembly wire harness
(white connector).
LIGHT
(3) #8 SCREWS
PANEL
(2) #8 SCREWS
PREPARE THE HOOD
AIR CHUTE
Remove Air
7
Chute - held in
place with one
(1) screw.
NOTE: Be care-
ful not to discon-
nect any wires.
Remove Baffle
8
from air chute.
BAFFLE
9
Rotate baffle. Re-
insert baffle into air
chute (as shown) so
that baffle tabs fit all
the way into slots in
air chute. An audible
"click" will be heard
when fully installed.
This will close off
the air flow through
the non-ducted slots
on top of hood.
10
Re-install air chute, re-connect wire
harness, and replace light panel.
NOTE: Be careful not to trap wires
between support fin and light panel.
ALLURE™ QS1 SERIES
RANGE HOOD
Page 3
BAFFLE
TABS
SLOTS
SUPPORT FIN