Technical Data - Festool CTH 26 E/a Original Instructions Manual

Mobile dust extractors
Hide thumbs Also See for CTH 26 E/a:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 15
English
Electrical outlet module with auto­
matic switch-on
3

Technical data

Mobile dust extractors
Power consumption
Maximum appliance socket connected load
Max. suction capacity (air), turbine
Max. vacuum, turbine
Filter surface area
Suction hose
Length of the net cable
Sound pressure level as per EN 60704-2-1 / Uncertainty K
Protection category
Container capacity
Dimensions L x W x H
Weight
Ø
21 mm
27 mm/IAS
32 mm
36 mm
42 mm
50 mm
[3] The suction capacity and vacuum are dependent on the selected hose diameter. For more information please refer to page 7.
16
[3]
1
WARNUNG
CH, DK
GB 240 V/ 110 V
CTH 26 E/a
CTH 48 E/a
CTH 26 E/a
CTH 48 E/a
CTH 26 E/a
CTH 48 E/a
Minimum volume flow
[m
3
/h]
25
41
58
73
100
141
≤ 0.1 mg/m
3
(dust class H)
350 ‑ 1000 W
EU
1800 W/ 500 W
234 m³/h (3900 l/min)
D 27 / 32 mm x 3,5 m AS
71 dB(A) / 3 dB
630 x 365 x 540 mm
740 x 406 x 1005 mm
[l/s]
6.9
11.4
16.1
20.3
27.8
39.2
2400 W
1100 W
24000 Pa
6318 cm²
7,5 m
IP X4
26 l
48 l
13,9 kg
18,8 kg

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cth 48 e/a202403202404202405

Table of Contents