ELECTRICAL CONNECTION

1. Connect the Power Supply Cable to the range
hood. Attach the white lead of the power supply
to the white lead of the range hood (A) with a
wire nut (C). Attach the black lead of the power
supply to the black lead of the range hood
(B) with a wire nut (C). Connect the green (D)
ground wire under the green grounding screw.
2. Replace the junction box cover.
B
D

FINISH THE INSTALLATION

1. For recirculation installation only: Attach the
CHARCOAL FILTERS (not included) to both sides
of the blower. To do this, place the side of the
charcoal filter with the tabs against the side
of the blower. Align the double lines on the
charcoal filter with the "unlocked" symbol on
the blower. Push and twist downward until the
double lines align with the "locked" symbol on
the blower. Repeat on other side with second
filter.
For recirculation and ducted installation:
2. Replace the grease filters.
8
Installation Instructions
C
A
FINISH THE INSTALLATION
(Continued)
3. Using a flathead screwdriver, lift up the tabs on
the top of the canopy.
Tabs
4. To install the lower duct cover:
• Use a flat head screwdriver to push the
two tabs forward on the lower duct cover.
• Angle the duct cover to slide the tabs
under the ledge of the hood body. Seat the
back of the duct cover on the top of the
range hood between the edges and tabs.
5. Turn the power supply on. Turn on blower
and light. If the range hood does not operate,
check that the circuit breaker is not tripped
or the house fuse blown. If the unit still does
not operate, disconnect the power supply and
check that the wiring connections have been
made properly.