Tab. 4.5: Conducted Power- Radiated Power - Caen RFID Hex R1290I Technical Information Manual

Multipurpose rain rfid reader with poe
Table of Contents

Advertisement

Custom
The use of the Custom profile allows the user to upload his own scripts to the reader.
Choosing the Custom profile, the RFID Configuration submenu options are the following:
RF Output Power: the default RF Power is 40%. The RF Power value at power up is expressed as a
percentage value of the maximum RF output power. Through the RF Output Power submenu you can set the
power level emitted by the reader. You can change the default value using the drop-down menu:
 5%
 10%
 20%
 40%
 60%
 80%
 100%
The correspondent values are:

Tab. 4.5: Conducted power- radiated power

CONFIGURATION USING THE WEB INTERFACE - Hex R1290I Technical Information Manual
Conducted Power
Percentage
(mW)
5%
10%
20%
40%
60%
80%
100%
Radiated Power ETSI
(mW e.r.p.)
25
16
50
32
100
64
200
128
300
192
400
256
500
320
Radiated Power FCC
(mW e.r.p.)
18
36
72
144
215
287
359
35