Tab. 4.3: Epc Code Parameters - Caen RFID Hex R1290I Technical Information Manual

Multipurpose rain rfid reader with poe
Table of Contents

Advertisement

EPC code parameters
Using the table below you can customize the text of the code displayed on the screen:

Tab. 4.3: EPC Code parameters

EPC Code: enable or disable. By default, the EPC Code is enabled and the EPC code is displayed on the
screen. You can change the default value using the drop-down menu.
FORMAT: In the HID profile you can set different EPC formats:
 HEX: The EPC code is represented as a hexadecimal number. For example, an EPC Code of 96 bits
 ASCII: The EPC code is interpreted as 8 bits at a time, each byte being represented as ASCII
By default the EPC HID format is set to "HEX". You can change the default value using the drop-down menu.
OFFSET: optional. The "offset" indicates after how many characters start counting the "length" value. By
default the offset string is empty.
LENGTH: number of characters of the EPC code to be displayed counting from the "offset". If not set, all the
EPC code is displayed. By default the length string is empty.
GROUP: the EPC code characters are grouped according to the value set in "group". By default the group
string is empty.
SEPARATOR: separator used to distinguish groups. By default the separator string is empty.
PREFIX: The PREFIX option permits to specify a string of maximum 7 characters to add before the EPC when
a tag is read.
The following list shows the accepted characters for the prefix:
'a', 'b', 'c', 'd', 'e', 'f', 'g', 'h', 'i', 'j', 'k', 'l', 'm', 'n', 'o', 'p', 'q', 'r', 's', 't', 'u', 'v', 'w', 'x', 'y', 'z', 'A', 'B', 'C', 'D', 'E',
'F', 'G', 'H', 'I', 'J', 'K', 'L', 'M', 'N', 'O', 'P', 'Q', 'R', 'S', 'T', 'U', 'V', 'W', 'X', 'Y', 'Z', '0', '1', '2', '3', '4', '5', '6', '7', '8',
'9', '{', '|', '}', '!', '"', '#', '$', '(', ')', '*', '+', ',', '.', '/', ':', ';', '=', '?', '@', '[', ']', '^', '_', '-'
By default the prefix string is empty.
POSTFIX: The POSTFIX option permits to specify a string of maximum 7 characters to add after the EPC when
a tag is read.
The following list shows the accepted characters for the postfix:
'a', 'b', 'c', 'd', 'e', 'f', 'g', 'h', 'i', 'j', 'k', 'l', 'm', 'n', 'o', 'p', 'q', 'r', 's', 't', 'u', 'v', 'w', 'x', 'y', 'z', 'A', 'B', 'C', 'D', 'E',
'F', 'G', 'H', 'I', 'J', 'K', 'L', 'M', 'N', 'O', 'P', 'Q', 'R', 'S', 'T', 'U', 'V', 'W', 'X', 'Y', 'Z', '0', '1', '2', '3', '4', '5', '6', '7', '8',
'9', '{', '|', '}', '!', '"', '#', '$', '(', ')', '*', '+', ',', '.', '/', ':', ';', '=', '?', '@', '[', ']', '^', '_', '-'
By default the postfix string is \r\n\ (see the following table Tab. 4.4: Escape Sequences supported page 33).
CONFIGURATION USING THE WEB INTERFACE - Hex R1290I Technical Information Manual
long corresponds to 24 hexadecimal digits (96/4=24).
character. For example, an EPC Code of 96 bits corresponds to a string of 12 ASCII characters (96/8
= 12).
Warning: if you are using a qwerty keyboard, pay attention that it is a standard qwerty keyboard
because if not the conversion of symbols could create display problems.