Mixing Valve
Description
No. of wires
Mixing valve
B5: Neutral (N)
B3: CCW (L2)
B2: CW (L1)

Example of sensor installation (TW3 / TW4)

Weld the sensor holder on the selected location of the pipe and then insulate it.

When the pipe is a copper pipe

Pipe
Sensor
holder
Sensor clip
Insulator
• When the holder sensor cannot be welded on the pipe, fix the senor with aluminum tape and insulate it.
NOTE
36
Max. current
4
22 mA
1. Before the installation, control kit should be turned off.
2. Using the appropriate equipment to correct position of terminal
Sensor
Aluminum tape
Thickness
2
> 0.75 mm
, H05RN-F or H07RH-F
block as shown on the diagram.

When the pipe is not a copper pipe

Pipe
Sensor
Supply Scope
Field supply (230 V~, Input)
Sensor
Rubber tape
Cable-tie
Insulator
Sensor