12.11 Display messages

NOTE - - - - - Here follows a list of alarm messages (in addition to
those explained before) that can be displayed and the
relative machine conditions.
STANDBY: the machine is switched off (the main switch is on
"I") and the automatic switching-on/off functions enabled (Pr.
12.7.1).
ANTI-FREEZING: the machine is switched off (the main switch
is on "I") and the function protecting boilers from icing-up is
enabled (Pr.12.7.1).
PROGRAMMED CLEANING: it is displayed when the machine
is performing the automatic cleaning of the brew group (Pr.
12.7.1).
ADD COFFEE: the machine, during the grinding, detects the
lack of coffee beans in the relative container (6).
FILL CIRCUIT: this message is displayed if the machine detects
the lack of water in the boilers during a beverage brewing.
After checking if there is actually water in the supply network,
press the button
( ^ in the COFFEE version), until water co-
mes out properly from the spout (11) and from the brew group
(22). In the "COFFEE" version the water comes out only from
the brew group
PROGRAMMING: it is displayed during the machine program-
ming (Pr. 12.6).
REMOVE GROUNDS: it is displayed if the dump box (16) is
almost full (the machine performed the programmed number of
brewings).
More brewings can anyway be performed.
OUT OF SERVICE – REMOVE GROUNDS: the dump box (16)
is completely full (the machine performed the programmed num-
ber of brewings).
The machine is blocked and no more brewings can be perfor-
med until the dump box is emptied.
CLOSE DOOR: the door (14) is not properly closed.
INSERT BOX: the dump box (16) is not properly inserted.
INSERT DRIP TRAY: the drip tray (12) is not properly inserted.
INSERT GROUP: the brew group (27) is not properly inserted.
GROUP ERROR: the brew group (27) is not properly perfor-
ming his working cycle; switch the machine off and call the
AUTHORIZED CUSTOMER SERVICE CENTER.
PUMP ERROR: one of the pumps is damaged. Switch the ma-
chine off and call the AUTHORIZED CUSTOMER SERVICE CEN-
TER.
SENSOR ERROR 01: is displayed when a temperature sensor
fails. Switch the machine off and call the AUTHORIZED CU-
STOMER SERVICE CENTER.
TEMPER. ERROR 01: is displayed when one of the boilers resi-
stance is damaged. Switch the machine off and call the AU-
THORIZED CUSTOMER SERVICE CENTER.
DESCALING: it is displayed when the machine needs a desca-
ling intervention, and after performing the programmed num-
ber of brewings. Switch the machine off and call the AUTHORI-
ZED CUSTOMER SERVICE CENTER.
The descaling interventions are set on working cycles of the
machine, and can be programmed by the maintenance techni-
cian.
MAINTENANCE: it is displayed when the machine needs main-
tenance and after performing the programmed number of
brewings. Switch the machine off and refer to the AUTHORI-
ZED CUSTOMER SERVICE CENTER.
The maintenance interventions are set on working cycles of the
machine, and can be programmed by the maintenance techni-
cian.

12.12 Machine switching-off

Programmed automatic switching-off
This is possible when the function "AUTOM.SWITCHING-ON"
(Pr. 12.7.1) is enabled and the function "TIMES ON/OFF"
(Pr. 12.7.1) has been programmed .
At the programmed time the machine goes on "STANDBY".
Manual switching-off
This switching-off is necessary if the function "AUTOM.
SWITCHING-ON" (Pr. 12.7.1) is not enabled.
It can be obtained by switching both the main switch (18) and
the all-pole switch on the "0" position or by disconnecting the
plug.