Gravity Wall Furnaces
Specifications
Model
Color: Cabinet and Front Panel
Btu Input
Overall Dimensions (unit mounts between standard stud spacing)
Width Casing
Depth Casing
Height
Height with Optional Blower Kit
Shipping Weight, Lbs. (One Carton)
Accessories (State on Order)
Wireless Remote Wall Thermostat
750mv Wall Thermostat (Reed Switch)
750mv Wall Thermostat
Remote Bulb Thermostat
Blower Kit
Output, Cu. Ft./Min.
Rear Register Kit
Out-of-the-Wall Installation Kit
Minimum Clearance to Combustibles from:
Top
Each Side
Bottom of Unit to Floor Covering
Gas Inlet
Type of Gas (State on Order)
Iron Pipe Size (N.P.T.)
Venting
Size of Flue Collar (Type B)
Safety Control
Pilot and Main Burners Include Automatic Shutoff
Warranty
Combustion chamber carries a 10-year limited warranty.
All other parts carry a 1-year limited warranty.
† One blower may be purchased for each side.
** When the GWTW-2 Out-of-the-Wall kit is used,
the GWTR-1 Rear Register kit cannot be used.
GWTB-2 Blower
GWSG-T
Thermostat
For Your Safety
Due to high temperatures, the appliance should be located out of
traffic and away from furniture and draperies.
Children and adults should be alerted to the hazard of high surface
temperature and should be kept away to avoid burns or clothing
ignition.
Installation and repair should be done by a qualified service person.
918 Freeburg Ave. • Belleville, IL 62220-2623
618-233-7420 • FAX 618-233-7097
E-mail: info@empirecomfort.com
GWT-25
GWT-35
Beige
Beige
25,000
35,000
16"
6"
1
66
/
"
66
8
7
71
/
"
71
8
86
TRW
TRW
TMV
TMV
GWSG-T
GWSG-T
GWRB-T
GWRB-T
GWTB-2
GWTB-2
75
GWTR-1
GWTR-1
GWTW-2**
GWTW-2**
12"
4"
1
1
/
"
2
Natural or LP
Natural or LP
1
/
"
2
4" Oval
4" Oval
GWRB-T
Wall
Remote Bulb
Thermostat
This series is design certified in accordance with American National
Standards Institute Z21.86 (latest standard) and CSA2.32-(latest
standard) by the Canadian Standards Association, as a Vented Wall
Furnace.
The installation must conform to local codes. In the absence of local
codes, the installation must conform with American National Standard
(National Fuel Gas Code) known as NFPA 54 and ANSI Z223.1 (latest
edition) available from the American National Standards Institute, Inc.,
11 West 42nd St., New York, N.Y. 10036, or from the National Fire
Protection Assoc., Batterymarch Park, Quincy, Massachusetts 02269.
www.empirecomfort.com
25,000 to 50,000 Btu Models
GWT-50
Dual Wall
Beige
50,000 (Total)
25,000 (Each Room)
16"
16"
6"
6"
1
1
/
"
66
/
"
8
8
7
7
/
"
71
/
"
8
8
86
133
TRW
TMV
GWSG-T
GWRB-T
GWTB-2†
75
75
N/A
N/A
12"
12"
4"
4"
1
1
1
/
"
1
/
"
2
2
Natural or LP
1
/
"
1
/
"
2
2
4" Oval
Inshot Burner &
Tubular Heat Exchanger
Read your Owner's Manual for complete installation and safety information.
115 VOLT OUTLET
BOX FOR OPTIONAL
HARDWIRING OF
OPTIONAL BLOWER
BOTTOM OF
HEADER PLATE
HEADER
NAILING
FLANGE
62
1
/
"
4
14
1
/
"
2
INSIDE
2 x 4 FLOOR PLATE
66
1
/
"
8
WALL
OPENING
Header is provided with furnace. However, if it is desired
to finish wall before furnace is delivered, the header may
be ordered and installed prior to delivery of furnace.
Note: Construction deeper than standard (2x4 stud) may
create installation problem. Contact Empire for
additional information. GWT-50 will not work on walls
with deeper than 2x4 construction.
* Purchase Locally
Note: Empire has a policy of constantly improving quality
and performance of its appliances, therefore, materials and
specifications are subject to change without notice.
Note: Units do not come with thermostats.
Note: A vent safety switch is standard on all models, automatically
shutting off the heater in the event of a blocked flue or incorrect
installation. (Example: Attaching a 90° elbow directly to the draft
diverter is an incorrect installation.) The flue pipe diameter must be as
large as the flue collar on the draft diverter and run as directly as
possible to the chimney with a minimum of elbows. Any flue pipe
passing through walls and roof must be "B" Type vent. The chimney
must extend at least two feet above the roof and any object or
building within ten feet of the chimney.
©Empire Comfort Systems, Inc. EHS-49 Rev. A 3/08
B-VENT WITH
BW ADAPTER*
BASE PLATE
GASKET FOR
HEADER
ASSEMBLY
HEADER
PLATE
2 x 4
STUDS
2 x 4 FLOOR PLATE

Advertisement

loading

This manual is also suitable for:

Gwt-35Gwt-50 dual wall