TK-3160
Item
Condition
7.DQT TCXO
TEST CH:Center
Balance Writing
[Wide]
[Narrow]
8.DQT VCO
TEST CH: Low
Balance
Adjust
[Wide]
LPF:3kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
PTT:ON
9.QT Deviation TEST CH:Low
Adjust
[Wide]
LPF:3kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
PTT:ON
10.DQT Deviation TEST CH: Low
Adjust
[Wide]
LPF:3kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
PTT:ON
11.Tone Deviation TEST CH:Center
Adjust
LPF:15kHz
[Wide]
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
PTT:ON
12.DTMF Deviation TEST CH:Center
Adjust
LPF:15kHz
[Wide]
HPF:OFF
PTT:ON
[Narrow]
TEST CH: Center
PTT:ON
13.MSK Deviation TEST CH: Low
Adjust
[Wide]
LPF:15kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
PTT:ON
40
ADJUSTMENT /
Test equipment
Power meter
Dev meter
Oscilloscope
AG
AF VTVM
Center
High
(3 points)
Center
High
(3 points)
Center
High
(3 points)
Center
High
(3 points)
调整
Measurement
Terminal
ANT
Programming
Software:KPG-82D
Adjustment
Parts
Method
Write
Make the
demodulation
wave into
square waves
0.8kHz
0.4kHz
0.75kHz
0.35kHz
3.0kHz
1.5kHz
3.0kHz
1.5kHz
3.0kHz
1.5kHz
Specifications/
Remark
200 hex
120 hex
±40Hz
±40Hz
±40Hz
±40Hz
±100Hz
±100Hz
±100Hz
±100Hz
±100Hz
±100Hz