Step 2: Install outdoor unit.
Fix the outdoor unit with anchor bolts (M10)
>600 mm
CAUTION
• Ensure to remove any obstacles that may block air circulation.
• Ensure you refer to the length specifications to ensure that there is
enough room for installation and maintenance.
Split Type Outdoor Unit
(Refer to Fig 14, 15, 16, 20 and Table 4)
W
Fig. 13.
Fig. 14.
Climate 5000 SCI – 6720887405 (2018/04)
Fix with bolts
H
W
H
D
Fig. 15.
Outdoor Unit Dimensions
W x H x D
760x590x285
810x558x310
845x700x320
900x860x315
945x810x395
990x965x345
938x1369x392
900x1170x350
800x554x333
845x702x363
946x810x420
946x810x410
952x1333x410
952x1333x415
Table 4. Length Specifications of Split Type Outdoor Unit
(unit: mm)
Vertical Discharge Type Outdoor Unit
NOTE :
The minimum distance between the outdoor unit and walls described in
the installation guide does not apply to airtight rooms. Ensure to keep
the unit unobstructed in at least two of the three directions (M, N, P)
(See Fig. 16)
M
N
Fig. 16.
Outdoor Unit Installation
A
B
Mounting Dimensions
Distance A
Distance B
530
290
549
325
560
335
590
333
640
405
624
366
634
404
590
378
514
340
540
350
673
403
673
403
634
404
634
404
P
11