Model and Serial Number Location
The rating plate is located under the cooktop.
When ordering parts for or making inquires about
your cooktop, always be sure to include the model
and serial numbers and a lot number or letter
from the rating plate on your cooktop.
Rating plate is
located under
the burner box of
cooktop.

Important Notes to the Installer

1. Read all instructions contained in these
installation instructions before installing the
cooktop.
2. Remove all packing material before connecting
the electrical supply to the cooktop.
3. Observe all governing codes and ordinances.
4. Be sure to leave these instructions with the
consumer.
5. Only certain cooktop models may be installed
over certain built-in electric oven models.
Approved cooktops and built-in ovens are listed
by the MFG ID number and product code.
6. All materials used in construction of cabinets,
enclosures, and supports surrounding the
product must have a temperature rating above
194°F (90°C).
Important Note to the Consumer
Keep these instructions with your User manual for
future reference.
IMPORTANT SAFETY
INSTRUCTIONS
• Be sure your cooktop is installed and
grounded properly by a qualified installer or
service technician.
• This cooktop must be electrically grounded
in accordance with local codes or, in their
absence, with the National Electrical Code
ANSI/NFPA No. 70—latest edition in the
United States.
6
WARNING!
The electrical power to the cooktop must
be shut off while line connections are
being made. Failure to do so could result in
serious injury or death.

Provide Electrical Connection

Install the junction box under the cabinet and run
120/240 or 120/208 Volt, AC wire from the main
circuit panel. NOTE: DO NOT connect the wire to
the circuit panel at this time.

Electrical Requirements

Observe all governing codes and local
ordinances.
1. A 3-wire or 4-wire single phase 120/240 or
120/208 Volt, 60 Hz AC only electrical supply
is required on a separate circuit fused on both
sides of the line (time-delay fuse or circuit
breaker is recommended). DO NOT fuse
neutral.
2. A circuit breaker or fuse rated at 40 Amp is
required for 36" models and 30 Amp for the
30" model.
NOTE: Wire sizes and connections must conform
with the fuse size and rating of the appliance in
accordance with the National Electrical Code ANSI/
NFPA No. 70–latest edition and local codes and
ordinances.
WARNING!
An extension cord must not be used with
this appliance. Such use may result in a
fire, electrical shock, or other personal
injury.
3. The appliance should be connected to the fused
disconnect (or circuit breaker) box through
flexible armored or nonmetallic sheathed cable.
The flexible armored cable extending from
this appliance should be connected directly to
the grounded junction box. The junction box
should be located as shown in Figure 2 with as
much slack as possible remaining in the cable
between the box and the appliance, so it can
be moved if servicing is ever necessary.
4. A suitable strain relief must be provided
to attach the flexible armored cable to the
junction box.
AA-2194923-3