Connection Module

The connection module is an optional accessory that connects to the camera and
provides the following connections:
• SERVER - for the connection to the AXIS 213
• 2 Digital inputs
• VIDEO IN
• RS-232C serial port
The connection module is configured and controlled via the camera's user interface.
Notes:
• Use an electret microphone. The microphone will be powered by the module through a 9.4k
• Use amplified speakers only, stero or mono plug

AUDIO IN/OUT

1. Connect a microphone (not supplied) to the AUDIO IN socket.
2. Connect a loudspeaker (not supplied) to the AUDIO OUT socket (amplified
speakers only).

Inputs and outputs (I/Os)

The I/Os are used in applications for, e.g. event triggering, time lapse recording, alarm
notification via email, image storage to FTP locations.
• Input - e.g. a pushbutton. If the button is pressed, the state changes, and the
input will be active (shown under Event Configuration > Port Status).
• Output - e.g. an alarm device that can be activated from Output buttons on
the Live View page, or as an action for an Event Type. If the alarm device is
activated, the output will show as active (under Event Configuration > Port
Status)
I/O
Description
Alarm In 1,2
Connect to GND to activate or leave floating (unconnected) to deactivate.
Alarm GND
Alarm Out
Active output, electrical connection between A and B. Non active output, no connection
1A,1B;2A,2B;3A,3B
between A and B.
Imax=100mA, VMax=24V
AXIS 213 - Connection Module
• AUDIO IN/OUT
• 3 Relay outputs
• VIDEO OUT