Moving or Copying Results to a Memory Card
(DTX-1800, DTX-1200)
To move or copy all results from internal memory to
the memory card:
1
Turn the rotary switch to SPECIAL FUNCTIONS.
2
Select Move/Copy Internal Results; then select an
option:
Move to Memory Card: Moves all results and
their folders to the memory card and deletes
all results from internal memory.
Copy to Memory Card: Copies all results and
their folders to the memory card.
Delete from Internal Memory: Deletes all
results from internal memory.
The tester displays a message if it cannot move or copy
a result. This occurs in the following cases:
A result with the same ID and timestamp already
exists on the memory card.
The memory card is full.
The memory card is not formatted or is damaged.
Viewing and Managing Saved Results
Deleting Results
To delete results:
1
Turn the rotary switch to SPECIAL FUNCTIONS.
D
2
Use
to highlight View/Delete Results;
H
then press
.
J
3
If necessary, press
result(s) you want to delete.
K
4
Press
Delete; then use
option:
Current Result: Deletes the result highlighted
on the previous screen.
All Results in Folder: Deletes all results in the
current folder.
All Results in Tester: Deletes all results in
internal memory. For the DTX-1200 and
DTX-1800, this option also deletes all results
on the memory card if one is present.
Current Folder: Deletes the current folder and
all its contents.
L
5
Press
Delete.