(31) False air intake
Technical data
Wet/dry dust extractor
Article number
Rated power input
Frequency
Container volume (gross)
Net volume (liquid)
Dust bag volume
A)
Max. vacuum
– Dust extractor
– Turbine
A)
Max. flow rate
– Dust extractor
– Turbine
Automatic start/stop
Weight according to EPTA-Procedure 01:2014
Protection class
Protection rating
A) Measured using a vacuum hose 3 m long and 35 mm in diameter
The specifications apply to a rated voltage [U] of 230 V. These specifications may vary at different voltages and in country-specific models.
A)
Automatic start/stop
Rated voltage
EU
220–240 V
UK
240 V
CH
230 V
A) Permitted connected load of the connected power tool (country-specific)
Noise/Vibration Information
Noise emission values determined according to EN
60335-2-69.
Typically the A-weighted sound pressure level of the dust ex-
tractor is 74 dB(A). Uncertainty K = 2 dB. The noise level
when working can exceed the volume stated. Wear hearing
protection!
Vibration total values a
(triax vector sum) and uncertainty K
h
determined according to EN 60335-2-69:
2
2
a
 < 2.5 m/s
, K = 1.5 m/s
.
h
Assembly
Pull the plug out of the socket before cleaning or per-
u
forming maintenance on the vacuum cleaner, making
tool adjustments, changing accessories or putting
away the vacuum cleaner. This safety measure prevents
the vacuum cleaner from being started accidentally.
Bosch Power Tools
a) Accessories shown or described are not included with the
product as standard. You can find the complete selection of
accessories in our accessories range.
GAS 15
3 601 JE5 0..
W
1100
Hz
50–60
l
15
l
8
l
8
kPa
22
kPa
22
l/s
33
l/s
53
kg
9.6
/ II
IPX4
Maximum power
Minimum power
2100 W
100 W
1760 W
100 W
2100 W
100 W
Fitting the vacuuming accessories (see figure A)
The vacuum hose (16) is equipped with a clip system which
can be used to connect vacuuming accessories (dust extrac-
tion adapter (14), curved nozzle (17)).
Fitting the nozzles and tubes
– Push the curved nozzle (17) onto the vacuum hose (16)
until you hear both snap fasteners (26) on the vacuum
hose engage.
– Then attach the required extraction accessory (floor
nozzle, crevice nozzle, suction tube, etc.) firmly to the
curved nozzle (17).
– To remove the accessory, press the snap fasteners (26)
inwards and pull apart the components.
Fitting the dust extraction adapter
GAS 15
– Push the dust extraction adapter (14) onto the vacuum
hose (16) until you hear both snap fasteners (26) on the
vacuum hose engage.
English | 17
GAS 15 PS
3 601 JE5 1..
1100
50–60
15
8
8
22
22
33
53
9.6
/I
IPX4