6
|
Application guidelines
6.4.6 DHW pump for tank preheating
6.5 Setting up the energy metering
Installer reference guide
52
Configuration
The outdoor unit can control DHW pump operation. For more information, see
4
"11 Configuration" [
123].
INFORMATION
Restriction: Only applicable in case of stainless steel tanks (EKHWS*D*).
Setup
a
b
a DHW tank
b Cold water IN
c Hot water OUT (shower (field supply))
d Motorised 3‑way valve (field supply)
e DHW pump (field supply)
f Non‑return valve (field supply)
▪
The DHW pump is field-supplied and its installation is the responsibility of the
installer. For the electrical wiring, see
4
pump" [
113].
Configuration
The outdoor unit can control DHW pump operation. For more information, see
4
"11 Configuration" [
123].
▪
Via the user interface, you can read out the following energy data:
-
Produced heat
-
Consumed energy
▪
You can read out the energy data:
-
For space heating
-
For space cooling
-
For domestic hot water production
f
e
d
M
"To connect the domestic hot water
c
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06