Summary of Contents for NDS EndoVue Plus

  • Page 1 EndoVue® Plus 4K 32" USER MANUAL ENGLISH...
  • Page 3 Information in this document has been carefully checked for accuracy; however, no guarantee is given to the correctness of the contents. This document is subject to change without notice. NDS provides this information as reference only. Reference to products from other vendors does not imply any recommendation or endorsement.
  • Page 5: Table Of Contents

    Table of Contents Safety Information ................. . 1 Warnings and Cautions .
  • Page 6 ii | Table of Contents...
  • Page 7: Safety Information

    This symbol alerts the user that important information regarding the installation and/or operation of this equipment follows. Information preceded by this symbol should be read carefully. This symbol alerts the user that the user manual and translated copies are published on the NDS website at: www.ndssi.com/user-manuals/ This symbol warns the user that uninsulated voltage within the unit may have sufficient magnitude to cause electrical shock.
  • Page 8: Image Retention Notice

    EndoVue Plus 4K 32” Intended Use The EndoVue Plus 4K 32" is intended for use in a medical environment to display high quality video and graphics images. The EndoVue Plus 4K 32" is indicated for use in surgical procedures where a reference image is to be displayed.
  • Page 9: Vesa Compliant Display Mounting

    VESA Compliant Display Mounting EndoVue series displays are compliant with the VESA Mounting Interface Standard. EndoVue® Plus 4K 32" The EndoVue® Plus 4K 32" has MIS hole mount patterns configured to the size and weight of the display, suitable for stand, wall, or armature mounting. MIS-D 100 x 100 mm and MIS-E 200 x 100 mm interfaces are shown below. 100 mm M4 X 0.7 Thread...
  • Page 10: Enclosure Assembly And Cleaning

    Enclosure Assembly and Cleaning Cable Cover Installation 1. Connect power, control, and video cables before installing the cable cover. 2. Align the cable cover to the cable well recess on the back of the display. 3. Slide the cable cover forward into the recess, with cables positioned under the cut-out. 4.
  • Page 11: Display User Interface

    Display User Interface Display Keypad The Display Keypad is centered on the lower front surface of the display enclosure, providing controls for adjustment of display parameters using the On Screen Display (OSD) Menu system. Menu Navigation INPUT and MENU Buttons: Open OSD Menus To open the Input Menu, press the INPUT button.
  • Page 12: Display Menu

    Display Menu To open the Display Menu of the primary, press the MENU button (press twice for secondary). The Picture Menu displays by default, with details of the current video input listed across the top of the menu above the menu tabs. To select other menus, press the left or right buttons to highlight the menu tab, then press the SCROLL button to enter the menu.
  • Page 13 Color Menu Gamma Use to select a gamma setting. 1.8, 2.0, 2.2, 2.4 or 2.6: Preset gamma values Video: Linear gamma Look Up Table (LUT) PACS: DICOM gamma LUT This product is capable of displaying Radiology (PACS) images for reference purposes only. Color Temperature Use to select a preset color temperature: 5500, 6500, 8000, 9300: Preset color temperatures.
  • Page 14 Setup Menu Menu Position: To select from nine preset screen locations for display of the OSD menus, press the buttons. Language: To select one of 19 languages: English, German, French, Italian, Swedish, Spanish, Dutch, Portuguese, Norwegian, Danish, Finnish, Turkish, Greek Russian, Polish, Korean, Japanese, Simplified Chinese, Traditional Chinese, press the buttons.
  • Page 15 Defaults Menu Factory Defaults To return all changed parameter settings to factory preset values, press the button. The “Restoring Factory Defaults” message displays while processing. User Defaults To save changes to default parameters in a User Default profile, press the SCROLL button to select a User Defaults profile marked ***EMPTY*** and press the...
  • Page 16: Image Adjustment

    Image Adjustment Brightness/Contrast Button Press the (Brightness/Contrast) button once to access the Brightness control. Press the button twice to access the Contrast control, or press it three times to access the Backlight control. Press the buttons to adjust the controls. Brightness Control To adjust brightness of the designated input of primary, press the buttons.
  • Page 17: Connector Panel Overview

    Connector Panel Overview The EndoVue® Plus 4K 32" is available in two different input/output connector panel configurations: Part number 90K0089 – DisplayPort and HDMI inputs only Video inputs: • One DisplayPort 1.2 Input • One HDMI 2.0 Input Video Outputs: •...
  • Page 18: Endovue Connector Panel - With Quad-Link Sdi (90K0090)

    EndoVue Connector Panel - With Quad-Link SDI (90K0090) SDI-3 SDI-1 SDI-2 SDI-4 HDMI 2.0 24VDC DP 1.2 In Input SDI-1 SDI-3 HDMI 2.0 SDI-2 SDI-4 5VDC USB In Connector Types Inputs Connector Types DisplayPort 1.2 DVI-I, Digital 100 Ohm differential, Analog 75 Ohm terminated HDMI 2.0 HD-15, 75 Ohm terminated Four SDI Inputs...
  • Page 19: Cable Bend Radius

    Cable Bend Radius We recommend that the bend radius of metallic cables be no less than 63 mm (2.5 inches) or 7 times the diameter of the cable whichever is greater. The bend radius of Fiber Optic cables should be no less than 10 times the diameter of the cable.
  • Page 20 14 | Connector Panel Overview...
  • Page 21: Specifications

    Signals outside of any of the specified ranges may not be supported. EndoVue Plus 4K 32" Parts List by Region Part Number Item Name 90K0089 ENDOVUE PLUS 4K 32", AMERICA, JAPAN, BC-WK32-A1B00 90K0090 ENDOVUE PLUS 4K 32", QUAD-LINK SDI, AMERICA, JAPAN, BC-WK32-A1B20 Specifications | 15...
  • Page 22 16 | Specifications...
  • Page 23: Troubleshooting

    Troubleshooting Ghosting in Characters Ghosting in characters is usually attributed to reflections in the video cable or source. Use a high quality cable and, if possible, lower the vertical refresh rate. Lower scan rates can help eliminate reflections. Unlike a CRT, a flat- panel will not flicker at lower refresh rates (60 Hz is optimal), and data will always be frame converted to 60Hz.
  • Page 24 18 | Troubleshooting...
  • Page 25: Electromagnetic Compatibility Tables

    Electromagnetic Compatibility Tables All medical electronic devices must conform to the requirements of IEC 60601-1-2. Precautions, adherences to the Electromagnetic Compatibility (EMC) guideline information provided in this manual and verification of all medical devices in simultaneous operation are required to ensure the electromagnetic compatibility and co- existence of all other medical devices prior to a surgical procedure.
  • Page 26: Electromagnetic Emissions

    Electromagnetic Emissions Emissions Compliance Electromagnetic environment-- guidance RF emissions Group 1 The product uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby CISPR 11 electronic equipment.
  • Page 27: Electromagnetic Immunity

    Electromagnetic Immunity Guidance and Manufacturer’s Declaration: Electromagnetic Emissions The product is intended for use in the electromagnetic environment specified below. The customer or the user of the product should assure that it is used in such an environment. Immunity Test Immunity Test Electrostatic discharge (ESD) IEC 61000-4-2 ±2, ±4, ±6, ±8kV contract discharge...
  • Page 28: Recommended Separation Distances

    Recommended Separation Distances Recommended separation distances between portable and mobile RF communications equipment and the product The product is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the product can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the product as recommended below, according to the maximum output power of the communications equipment.
  • Page 29 Electromagnetic Compatibility Tables | 23...
  • Page 30 24 | Electromagnetic Compatibility Tables...
  • Page 31: Terms And Conditions

    Terms and Conditions Declarations of Conformity FCC and Council Directives of European Standards This device complies with Part 15 of FCC rules and 2017/745 Medical Device Regulation of European Union. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesirable results.
  • Page 32: Legal Statement

    NDS neither assumes nor authorizes any person to assume for it any other liabilities in conjunction with and/or related to the sale and/or use of its products. To ensure proper use, handling and care of NDS products, customers should consult the product specific literature, instruction manual, and/or labeling included with the product or otherwise available.
  • Page 34 +81 3 5753 2466 info@ndssi.com Oriental Media Center Suite 2302, Tower C No.4, Guang Hua Road Chao Yang District Beijing, 100026 China +86 10 8559 7859 info@ndssi.com NDS Quality System ISO 13485 FDA Registration #2954921 March 2021 60A1086 Rev B...