Nokia RM-11 Series Troubleshooting Manual page 46

Rf
Hide thumbs Also See for RM-11 Series:
Table of Contents

Advertisement

RM-11
Troubleshooting - RF
6. Select Rho ON , and click Execute .
Note: Be sure the "RHO command successful" message appears.
7. Measure the Tx Pout at the RF connector using the 8960 Call Box.
Cell band Tx Pout = +11dBm
PCS band Tx Pout = +12dBm
If you do not see these powers, probe the Tx path to find out where the signal stops.
1. After Local Mode/Main Mode/and CDMA Control are activated, adjust the PDM
values on the RF PDM dialog box.
MIN
MIN
MAX
MAX
Note: If you do not measure the correct Tx power at the RF connector, use
the RF probe to determine where the failure occurs.
Local Mode (either PCS channel 600 or Cell chan 384):
PA Gain PDM = +220
RF AGC PDM = -512
IF AGC PDM = -105 (PCS), -135 (Cell)
© 2005 Nokia Corporation
Page 46
MIN
MIN
MAX
MAX
MAX
MAX
MIN
MIN
Confidential
CC Technical Documentation
Issue 2 09/2005

Hide quick links: