6
• Non-Incendive
FM-United States Nonincendive for Class I, Division 2, Groups A, B, C & D Hazardous
Certificate no.:
FM-Canada
Certificate no.:
• Compliancy
• Recommendations and guidelines
NAMUR
IM 12B06W03-01E-E
(Classified) Location, Indoors/Outdoors with a Temperature code T6/
T5/T4 for -20°C ≤ Ta ≤ +55°C when connected in accordance with
Control Drawing D&E 2019-012-A60.
By applying:
- FM3600: 2018 Electrical Equipment for Use in Hazardous (Classified)
Locations, General Requirements
- FM3611: 2018 Nonincendive Electrical Equipment for Use in Class
I and II, Division 2, and Class III, Divisions 1 and 2, Hazardous
(Classified) Locations
- FM3810: 2018 Electrical and Electronic Test, Measuring and Process
Control Equipment
- UL 121201: 2017 Nonincendive Electrical Equipment for Use in
Class I and II, Division 2, and Class III, Divisions 1 and 2, Hazardous
(Classified) Locations
- ANSI/ISA 61010.1: 2012 Safety requirements for electrical
equipment for measurement, control and laboratory use – Part 1:
General requirements
FM19US0166X. For Specific conditions of Use refer to section 1-4.
Nonincendive for Class I, Division 2, Groups A, B, C & D Hazardous
(Classified) Location, Indoors/Outdoors with a Temperature code T6/
T5/T4 for -20°C ≤ Ta ≤ +55°C when connected in accordance with
Control Drawing D&E 2019-012-A60.
By applying:
- CSA-C22.2 No. 0.4: R2013 Bonding of Electrical Equipment
CSA-C22.2 No. 213: 2017 Nonincendive Electrical Equipment for
Use in Class I, Division 2, Hazardous Locations
- C 22.2 No. 61010.1: 2012 Safety requirements for electrical
equipment for measurement, control and laboratory use – Part 1:
General requirements
- C22.2 No. 94.2: 2015 Enclosures for Electrical Equipment,
Environmental Considerations
FM19CA0089X. For Specific conditions of Use refer to section 1-4.
- AS/NZS CISPR 11
- KC Registration of broadcasting and communication equipment
KCC-R-R-YPA-BA11
Precompliance checked by applying:
- NAMUR NE21: 2017 Electromagnetic compatibility (EMC) of
industrial process and laboratory.