Protection Configuration Screen
The protection configuration screens (Figure 21 and
22) provides status and control details for fault
protected circuits.
11/23/99
00:32:51
-------------------------------- SHELF STATUS -------------------------------
|
SLOT ->
|
STATUS ->
|_____________________________________________________________________________|
^^—— = MAIN ACTIVE
Press:
"nnS" - select slot,
"M"
11/23/99
00:29:33
_____________________________________________________________________________
|
PROTECTION OPTIONS
|
-----------------------------------------
|
1. PROTECTION MODE
|
2. MINIMUM HOLDIN TIME
|
3. BER THRESHOLD
|
4. BER INTERVAL
|
5. LOCKIN HOURS
|
6. SWITCH TO AUX LIMIT
|
7. LOCKIN CHECK INTERVAL = 20
|________________________________________________|____________________________|
LOCKIN OPTIONS:
SYSTEM CURRENT STATUS : NORMAL OPERATION
------------------------------------ SHELF STATUS ---------------------------
|
SLOT ->
|
STATUS ->
|_____________________________________________________________________________|
^^—— = MAIN ACTIVE
Press:
"nnS" - select slot,
"M"
61221051L1-5A
PROTECTION
[ SLOT 2
________________________________________________
|
PROTECTION OPTIONS
|
-----------------------------------------
|
1. BER THRESHOLD
|
2. BER INTERVAL
|
|
|
|
|
|________________________________________________|
MAIN CARD CAN ONLY SET THE BER OPTIONS.
01
02
03
04
05
^^----
**
**
——^^ = AUX ACTIVE
"nP" - select option,
- main menu,
"I"
- implement and save current changes :

Figure 21. Protection Screen (Main)

PROTECTION
[ SLOT 3
CURRENT SETTINGS
= AUTO
= 01
MIN(S)
= 1E-7
= 15
MINS
= 12
HR(S)
= 09
(1-9)
MIN(S)
IF 09 SWITCHOVERS OCCUR IN 20 MINUTES,
01
02
03
04
05
^^----
**
**
——^^ = AUX ACTIVE
"nP" - select option,
- main menu,
"I"
- implement and save current changes :

Figure 22. Protection Screen (Aux)

61221051L1-5, Issue 1
The screens provided below are typical and
may vary slightly depending on the hardware
installed. For Instance, if HDSL2 H2TU-C
equipment is installed, certain screens will
change to indicate only 1 loop present.
CONFIGURATION
]
CURRENT SETTINGS
=
1E-7
=
15 MINS
06
07
08
09
10
11
**
**
**
**
**
** = STANDARD HTU-C
CONFIGURATION
]
|
SWITCHOVER HISTORY
|
----------------------
|
SWITCHOVERS -> 00
|
REVERSIONS
|
FAILURES
|
LOCKOUTS
|
|
|
LOCKIN FOR 12 HOURS.
06
07
08
09
10
11
**
**
**
**
**
** = STANDARD HTU-C
NOTE
SHELF ADDRESS = 00
|
|
|
|
|
|
|
|
|
12
13
|
**
**
|
SHELF ADDRESS = 00
|
|
|
-> 00
|
-> 00
|
-> 00
|
|
|
|
12
13
|
**
**
|
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

E220 hfac hdsl2

Table of Contents