Figure 16. Loopback Status Summary Screen; Figure 17. Slot Specific Loopback Options Screen - ADTRAN E220 HFAC HDSL Installation And Maintenance Manual

Hdsl / hdsl2 fuse alarm control unit
Hide thumbs Also See for E220 HFAC HDSL:
Table of Contents

Advertisement

Loopback Status Summary Screen
Item selection 4, Loopback Control, from the Main
Menu displays the loopback status information for all
of the HTU-C, HRE, and HTU-R units monitored by
the HFAC. Loopback Status (On, Off, or Not
available) is presented for loopbacks to both the
network and the customer at both the HTU-C, HRE,
and HTU-R. Figure 16 illustrates the Loopback
Status Summary Screen.
Loopback Options
By pressing a slot number followed by an S from the
11/23/99
00:19:57
SLOT#
-----
1 :
2 :
3 :
4 :
5 :
6 :
7 :
8 :
9 :
10 :
11 :
12 :
13 :
ON
OFF
xxxx
----
11/23/99
00:21:48
—>|
NET |
<—|
Press
61221051L1-5A
LOOPBACK STATUS
HTU-C
HRE1
<--
-->
<--
NET
CUST
NET
-------------
----
---
---
----
OFF
OFF
xxxx
OFF
OFF
xxxx
OFF
OFF
OFF
OFF
OFF
xxxx
---
---
----
OFF
OFF
xxxx
OFF
OFF
OFF
OFF
OFF
xxxx
OFF
OFF
xxxx
OFF
OFF
xxxx
OFF
OFF
xxxx
OFF
OFF
xxxx
=
LOOPBACK ON
=
LOOPBACK OFF
=
NOT AVAILABLE
=
EMPTY SLOT

Figure 16. Loopback Status Summary Screen

LOOPBACK OPTIONS
_____
_____
|HTU-C|
|HRE 1|
|
|
|
|
|
| LP1 |
| LP1 |
|<===>|
|<===>|
|
|
|
|
|
|
|
|
| LP2 |
|LP2
|<===>|
|<===>|
|
|
|
|
|
|
|
|
|_____|
|_____|
1) LOOPBACK TO NETWORK
2) LOOPBACK TO CUSTOMER AT HTU-C = UNAVAILABLE
3) LOOPBACK TO NETWORK
4) LOOPBACK TO CUSTOMER AT HTU-R = UNAVAILABLE
5) LOOPBACK TO NETWORK
6) LOOPBACK TO NETWORK
"nL"
-
Toggle Loopback(ex. 3L),
"P"
-
Previous Screen,
Figure 17. Loopback Options Screen
61221051L1-5, Issue 1
Loopback Status Summary Screen, you will be
presented with a slot-specific Loopback Options
Screen (Figure 17). Multiple loopbacks can be
initiated for each circuit. This screen graphically
depicts the loopback activated by showing through
reverse video, the path of the loopback and the
locations it loops to. Also, the status indication
changes from inactive to active. The initiation of a
loopback is accomplished by pressing the
corresponding number of the loopback desired,
followed by an L.
HRE2
HTU-R
<--
<--
NET
NET
----
-------------
----
----
xxxx
OFF
xxxx
OFF
xxxx
OFF
xxxx
OFF
----
----
xxxx
OFF
OFF
OFF
xxxx
OFF
xxxx
OFF
xxxx
OFF
xxxx
OFF
xxxx
OFF
PRESS
"nnS"
- Slot Select,
"M"
- Main Menu :
[ SLOT = 8
]
SHELF ADDRESS = 00
_____
_____
|HRE 2|
|HTU-R|
|
|
|
|
| LP1 |
|
|<===>|<--, |<—-
|
|
|
| |
|
|
|
| | CUST
|
| LP2 |
| |
|<===>|<--, |—>
|
|
|
|
|
|
|
|
|_____|
|_____|
AT HTU-C = UNAVAILABLE
AT HTU-R = ACTIVE
AT HRE1
= UNAVAILABLE
AT HRE2
= UNAVAILABLE
"nnS"
-
Select Slot,
"M" -
Main Menu :
SHELF ADDRESS = 00
-->
CUST
----
OFF
OFF
OFF
OFF
----
OFF
OFF
OFF
OFF
OFF
OFF
OFF
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

E220 hfac hdsl2

Table of Contents