Figure 20. Provisioning Screen - ADTRAN E220 HFAC HDSL Installation And Maintenance Manual

Hdsl / hdsl2 fuse alarm control unit
Hide thumbs Also See for E220 HFAC HDSL:
Table of Contents

Advertisement

Provisioning Summary Screen
Selection of item 8 from the Main Menu supplies
provisioning information on individual circuits being
accessed by the HFAC. Figure 20 is a slot-specific
provisioning screen showing the provision option
item, current settings, and hardware settings for that
particular circuit. A key at the bottom of the screen
describes the options associated with this screen.
Menu item 7 provides a means of provisioning
specific HTU-C units, from the HFAC, to enable or
disable various HTU-C alarms. This option is
different from the Disable Alarms option on the
HFAC Options Setup screen. This option sets the
selected HTU-C to enable or disable the alarms
presented on the HTU-C edge connector pins 20 and
21 (closure between pins) and edge connector pin 1
(closure to ground).
The Enable All selection permits alarms to be
presented on the aforementioned edge connector pins
11/23/99
00:28:34
___________________________________________________ ______________________
|
|
PROVISIONS
|
-----------------------
|
1.
DSX-1 LINE BUILDOUT
|
2.
DSX-1/DS1 LINE CODE
|
3.
DSX-1/DS1 FRAMING
|
4.
LOOPBACK TIMEOUT
|
5.
DS1 OUTPUT LEVEL
|
6.
NIU LOOPBACK
|
7.
DS0 BLOCKING
|
|
|
CHANNELS
|
|___________________________________________________|______________________|
Press :
"nnS"
18
PROVISIONING
CURRENT SETTINGS
----------------
=
399-533 FEET
=
B8ZS
=
ESF
=
NONE
=
-15 dB
=
DISABLED
00000000 00000000 00000000
1
"X" BLOCKS THE CHANNEL.
"nP"
to change corresponding provision (ex. 5P)
"H"
to copy hardware settings to current settings
"I"
to implement and save current setting changes
select slot,
->

Figure 20. Provisioning Screen

61221051L1-5, Issue 1
due to faults at any of the HDSL / HDSL2 loop, DSX-
1, or DS1 locations. The Disable All disables all
alarms due to external faults or faults within the
HDSL / HDSL2 equipment or loops.
The Disable EXT selection allows only alarms caused
by faults in the HDSL / HDSL2 equipment or HDSL /
HDSL2 loops and suppresses alarms caused by
external DSX-1 or DS1 faults.
ADTRAN 220/E220 H2TU-Cs support an
EXTERNAL LBO option for use in legacy
220 ORB shelves. The ADTRAN E220 shelf
does not require the EXTERNAL LBO option.
The E220 HFAC will not allow the selection
of the EXTERNAL LBO setting when
initiated through the HFAC terminal screen.
It should be noted that the HFAC will not
automatically override an EXTERNAL LBO
setting.
[ SLOT = 8
]
SHELF ADDRESS = 00
|
|
HARDWARE SETTINGS
|
-----------------
|
399-533 FEET
|
B8ZS
|
ESF
|
NONE
|
-15 dB
|
DISABLED
|
|
|
24
|
|
"M"
main menu
<-
NOTE
|
|
|
|
|
|
|
|
|
|
|
|
|
|
61221051L1-5A