The operation mode judging temperature and standard setting temperature can be increased by 2°C
permanently, by open the circuit of JX03 at indoor unit's printed circuit board.
12.5 Indoor Fan Speed Control
•
Indoor fan speed can be set using remote control.
12.5.1
Fan Speed Rotation Chart
Fan Speed (rpm)
Fan Speed (rpm)
SHi
Hi
Me
HLo
CLo
Lo-
SLo
SSLo
QSHi
QHi
QMe
QHLo
QLo
SHi
Hi
Me
HLo
CLo
Lo-
SLo
SSLo
QSHi
QHi
QMe
QHLo
QLo
CS-A9MKD
1080
1040
870
770
730
690
670
300
1010
970
800
700
660
CS-A18MKD
CS-A24MKD
1310
1240
1140
1100
1040
850
650
300
1220
1150
1050
950
950
55
CS-A12MKD
1120
1100
950
840
800
760
740
300
1050
1030
880
770
730
CS-A28MKD
1530
1540
1390
1500
1270
1380
1230
1330
1150
1250
940
1030
720
810
300
300
1440
1450
1300
1410
1180
1290
1060
1160
1060
1160