8. Wiring Connection Diagram
8.1
CS-A9MKD CU-A9MKD
Resistance of Indoor Fan Motor Windings
MODEL
CONNECTION
BLUE-YELLOW
YELLOW-RED
Note: Resistance at 20°C of ambient temperature.
Resistance of Outdoor Fan Motor Windings
MODEL
CONNECTION
BLUE-YELLOW
YELLOW-RED
Note: Resistance at 25°C of ambient temperature.
CS-A9MKD
CWA921434
351.3Ω
343.9Ω
CU-A9MKD
CWA951388J
285Ω
281Ω
Resistance of Compressor Windings
MODEL
CONNECTION
C-R
C-S
Note: Resistance at 20°C of ambient temperature.
26
CU-A9MKD
2PS156D3DA02
4.228Ω
3.841Ω