Fortinet FortiGate-7000F Series System Manual page 46

Hide thumbs Also See for FortiGate-7000F Series:
Table of Contents

Advertisement

FortiGate-7000F System Management Module
LED
Alarm
Temp
FortiGate-7121F System Guide
State
Off
Red
Amber
Solid green
Blinking green
Blinking red
Solid red
Description
No alarms
One or more analog sensors in the chassis or on a module in 
the chassis (other than PSUs) have surpassed a critical or 
non-recoverable (NR) threshold causing an alarm. When a 
critical threshold has been reached, it means that a condition 
has been detected that has surpassed an operating tolerance. 
For example, a temperature has increased above the allowed 
operating temperature range.
One or more analog sensors in the chassis or on a module in 
the chassis (excluding PSUs) has surpassed a major or 
critical (CR) threshold. Any sensor, including sensors on 
PSUs, has generated an alert. Sensor alert criteria is defined 
per sensor. For analog sensors, alerts usually mean passing 
an upper critical (UC) or lower critical (LC) threshold. For 
other sensors, an alert could mean a flag bit is indicating an 
anomaly.
All temperature sensors indicated acceptable operating 
temperatures. 
At least one temperature sensor is detecting a high 
temperature outside of the normal operating range. In this 
case an upper non-critical (UNC) temperature. The SMM 
increases fan speed to increase cooling and reduce the 
temperature.
At least one temperature sensor is detecting a temperature 
outside of the acceptable operating range. In this case an 
upper critical (UC) temperature. The SMM increases fan 
speed to the maximum level. This also indicates possible 
problems with the cooling system and could mean that the 
ambient temperature is too high.   A lso causes a major or 
critical (CR) alarm.
At least one temperature sensor is detecting a temperature 
outside of the allowed operating range. In this case an upper 
non-recoverable (UNR) temperature.   T he SMM increases fan 
speed to the maximum level. The temperature is high enough 
to potentially cause physical damage. Also causes a critical or 
non-recoverable (NR) alarm.
Fortinet Technologies Inc.
46

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fortigate-7121f

Table of Contents