Appendix

Address Formats For Supported Lighting Systems

The Address and Button # fields in the House Lighting Scenes dialog correspond to either the
lighting controller address and the preset number (as with AMX Radia), or the address of the
keypad and the keypad button that will be emulated (as with the LiteTouch controller).
The only valid keypad address characters are 0-9, A-F, and : (colon).
For reference, here are the formats for the various supported lighting systems:
Once the application entries are completed, the touch panel files, the DMS keypad files, source
code, NetLinx Studio project file, text files (CD titles, tuner presets, etc.), and report file are all
created.

Note for ALD-D48 Lighting Systems

For ALD-D48 Lighting Systems, each button on the touch panel or keypad corresponds to a
lighting preset.

Note for Radia Lighting Systems

On Radia lighting systems, channels 1-128 represent Radia lighting presets 1-128. If a channel is
on, then the corresponding preset is on. However, on startup NetLinx resets all channels to 0 (OFF).
Radia does not report the status of its channels when the master comes up, and consequently the
software believes the state of all of the presets is OFF. Therefore, until a preset changes in the
system, the channel states are not reported.
Design XPress Installer's Guide
Lighting Controller
AMX ALD-D48
AMX Radia
Clipsal C-Bus
DynaLite
LiteTouch 5000LC
Lutron GRAFIK Eye
Lutron Homeworks Interactive Processor:Link:Keypad (positive integers)
Lutron RadioRA
Vantage Qlink
For instructions on developing NetLinx code to program scenes for the D48, refer to Tech
Note # TN 543, available via www.amx.com (Dealers > Tech Center > Tech Notes).
For detailed configuration information on the ALD-D48, refer to the ALD-D48 Network
Lighting Solution Instruction Manual, also available via www.amx.com (Dealers > Tech
Center > Tech Docs > Instruction Manuals).
Address Format
The Address value is fixed at a value of 1 and is
disabled.
AXlink Device ID (1-255).The Address is the
AXlink device ID of the Radia MC.
Group Address:Network Address
(network address always = zero)
DynaLite area (positive integer)
Keypad Address (3 nibble hex value
Master (positive integer)
Keypad Address (positive integer)
Note: keypad address 12 is reserved as the
RS-232 RadioRA interface. This interface is a
virtual keypad, and does not contain any
buttons.
Master:Keypad (positive integers)
Appendix
DXP-Example
1 (read-only)
96
A1:00
18
A3E
17
1:4:9
12
1:5
15

Advertisement