  • Page 1 FULL DC INVERTER SYSTEMS USER‘S MANUAL WIRE CONTROLLER FOR HYDROBOX SDV4-140HB3P C O M M E R C I A L A I R C O N D I T I O N E R S S D V 4...
  • Page 2 Original instructions Thank you for purchasing our product. Please read this manual carefully before running the unit and keep it for future reference.
  • Page 3: Table Of Contents

    CONTENTS Safety precautions..............Technical data and characteristic......... Overview ................Operation instruction............Error handling................ ● This manual gives detailed description of the precautions that should be brought to your attention during operation. ● In order to ensure correct service of the wired controller please read this manual carefully before using the unit.
  • Page 4: Safety Precautions

    1. Safety precautions WARNING Please assign the distributor or professionals to install the device. Imporper installation may lead to electric shock or fire. Do not install the unit in a place vulnerable to leakage of flammable gases. Once flammable gases are leaked and left around the wire controller, fire may occur.
  • Page 5: Technical Data And Characteristic

    2. Technical data and characteristic 2.1 Technical data 1) Input voltage: 10VAC. 2) Operating environment temperature of wired controller: -10°C~+43°C. 3) Operating RH of wired controller: RH 40%~RH90%. 2.2 Characteristic 1) Touch key operation; 2) LCD displays operation parameters; 3) Multiple timer; 4) Real-time clock (battery life:5~8 years).
  • Page 6: Overview

    3. Overview MODE FUNCTIONS (Long press 3s (Long press 3s for unlocking) for cancelling timing) Fig.3-1 1. Operation icon 7. Water Level Indication 13. FUNCTIONS key 2. Mode area 8. Clock 14. Add and Reduce key 3. Setting temperature 9. Water temp. 15.
  • Page 7 Operation icon : Indicate unit ON and OFF status; the icon displays when the unit is on and does not display when the unit is off; Mode area: Indicate the main unit operating mode; Setting temperature: 2 status can be displayed: Timing ON/OFF indication : Indicate the timing information;...
  • Page 8 : Displays when no key operation for 2 minutes and all keys are locked. Press and hold “OK” key for 3 seconds to unlock; : Displays when error or protection occurs and means the unit need maintainence by professionals. On-line unit qty. indication: Under normal status display the quantity of units connected to the wire controller;...
  • Page 9: Operation Instruction

    Add and Reduce key: Move up or move down values of temperature, timing, water level etc; Turn over #0 #15 units under check status; Cancel key: Press this key to cancel parameter setting under setting status; Press and hold this key for 3 seconds to cancel timing when timing is valid; Mode key: Choose water heating mode of the unit (floor heating and water cooling are not available).
  • Page 10 4.2 Setting operating modes and parameters Press “FUNCTIONS” key to enter the operation mode and parameters setting. The setting contents will change as the following order each time the key is pressed: TEMP. DIFFERENCE MODE NOTE The setting options in the dotted line frame CYCLE are not general setting.
  • Page 11 2) Set the stop and restart temperature 3) Timing setting: 3 timing periods can be difference (Valid when the wire controller set on the wire controller: Timer 1, is set to 5) Timer 2, Timer 3. These 3 timers can Continuous press “FUNCTIONS”...
  • Page 12 At this time the hour of the clock will flash, it At this time the hour of the clock will flash, means the current setting is the hour of the which means the current setting is the hour Timer 2 “On”. of Timer 1 “On”, press the “▲”...
  • Page 13 Example of Timing setting Main page Press “FUNCTIONS” key twice to enter hour setting interface of “Timer 1 On” Press the “▲” or “▼” key to set the hour number of “Timing 1 On” to be 07 Press “ ” key to enter minute setting interface of “Timer 1 On”, adjust the minute number to be 10 Press “...
  • Page 14 During any period of timing setting to press “OK” key , the timing periods which have been set will be effective (only if the “On” and “Off” of one timing period have been set, the setting is effective). Check timing information: to check the timing which has been set, press “◄” or “►” key under main page, the “...
  • Page 15 4) Set working mode(valid when wire controller set to 2,3,4) Press the Press “MODE” key to enter the working mode setting when the main unit is off power. key to adjust , press “OK” key or wait for 7 seconds to confirm and back to the “MODE”...
  • Page 16 Set clock CYCLE ONLINE QUANTITY HEAT WATER TEMP. MODE FUNCTIONS Press 4 times (Long press 3s (Long press 3s for cancelling timing) for unlocking) Fig.4-10 Press the “FUNCTIONS” key 4 times to enter clock setting. The hour of the clock will flash, which means the current setting is the hour of the clock, press the “▲”...
  • Page 17 4.3 check 1) Check function allows the user to check all the operating parameters, error and protection information of the main unit. 2) Enter method: press and hold “ ” key for 3 seconds to enter check FUNCTIONS interface, as the figure display: check CHECK icon...
  • Page 18 Operation capacity of outdoor unit. Setting temp. Water inlet temp. Water outlet temp. Water temp.in tank Condenser pipe temp.T2 Condenser pipe temp.T2B EXV opening The temperature difference of auto-restarting The cycle of auto-restarting Last one error or protection Last second error or protection Last third error or protection...
  • Page 19: Error Handling

    5. Error handling When the unit has error or protection, “ ” icon will flash. Press and hold “SET” key for 3 seconds to enter check status and then press the “▲” or “▼” key to check the unit of 0-15#. If the “error” icon is on, it means the corresponding unit has error or protection at that time.
  • Page 20 The value GWP: 2088 GWP = Global Warming Potential In case of quality problem or other please contact your local supplier or authorized service center. Emergency number: 112 PRODUCER SINCLAIR CORPORATION Ltd. 1-4 Argyll St. London W1F 7LD Great Britain www.sinclair-world.com This product was manufactured in China (Made in China).