Installation Of Outdoor Unit; Conditions Where Outdoor Unit Is Installed; Drill A Hole In The Wall - LG THERMA V HN0916T Installation Manual

Air-to-water heat pump
Table of Contents

Advertisement

INSTALLATION OF OUTDOOR UNIT

The outdoor unit of
Therefore, it is important to secure proper space around the outdoor unit and care for specific
external conditions.
This chapter presents a guide to install the outdoor unit, make a route to connect with the indoor,
and what to do when installed around seaside.

Conditions where Outdoor Unit is Installed

- If a sunroof is built over the unit to prevent direct sunlight or rain exposure, make sure that heat
radiation from the heat exchanger is not restricted.
- Ensure that the spaces indicated by arrows around front, back and side of the unit.
- Do not place animals and plants in the path of the warm air.
- Take the weight of the outdoor unit into account and select a place where noise and vibration
are minimum.
- Select a place so that the warm air and noise from the outdoor unit do not disturb neighbors.
300
F e
o b
s t a

Drill a Hole in the Wall

- If making a hole to the wall is required to connect pipe between the indoor unit and the outdoor
unit, please follow below descriptions.
Drill the piping hole with a Ø 70 mm hole core drill.
Piping hole should be slightly slant to the outdoor side to prevent raindrop into indoor side.
is installed outside to exchange heat with ambient air.
n c e
o r
c l e
s
700
Indoor
INSTALLATION OF OUTDOOR UNIT
300
600
Minimum service space
(unit : mm)
Wall
Outdoor
29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents