Installer setting

• You can set the product user functions.
• Some functions may not be displayed/operated in some product types.
Configuration
Function
Select Temperature Sensor
Use Heating Tank Heater
Mixing Circuit
Use External Pump
RMC master/slave
LG Therma V Configuration
General
Function
Forced operation
Pump Capacity
Pump Prerun/Overrun
Password Reset
Room Heating
Function
Heating temp. setting
Air heating set temp.
Water heating set temp.
TH on/off Variable, heating air
TH on/off Variable, heating water Heating Water Outlet Temperature TH On / Off Type
Pump setting in heating
Heater on temperature
Screed drying
Selection for setting temperature as air temperature or leaving
water temperature or air+leaving water temperature.
Determine the delay time of the electric heater for the water tank.
This function is to use mixing circuit function. Set enable/disable
mixing circuit function and valve closing time and hysteresis.
Set up to control an external water pump.
This function is to set master / slave to use two remote controllers
in one indoor unit.
This function can be set to save the environment settings of the
product for use in LG Therma V Configurator through SD Card.
(LG heating configurator)
Main water pump off After 20 consecutive hours, disable / enable the
logic that drives the water pump by itself.
Function to change Main water pump Capacity.
Set to reach the optimum flow rate by circulating the heating water
with the water pump before heat exchange. After the operation stop,
additional water pump is activated to circulate the heating water.
It is the function to reset (0000) the password when you forgot the
password set in the remote controller.
At the water control in heating mode, the control reference
water temperature position setting.
Adjusting range of 'Setting Air Temperature' in heating mode
Adjusting range of 'Setting Leaving water Temperature' in
heating mode.
Heating air temperature TH On / Off Type setting
Set water pump on/off interval option during thermo off
condition in heating mode
Setting outdoor air temperature where electric heater starts
operation.
This function controls floor heating to a specific temperature
for a certain period of time to cure floor cement.
INSTALLER SETTING
Description
Description
Description
105