Code Translator
Installation and Operation Instructions
The 2083/02 Code Translator is an interface unit used with American Dynamics Switching Systems. The unit translates codes
which then enable the use of American Dynamics equipment with that of Sensormatic Speed Domes and Mini Domes.

Advertisement

loading

Summary of Contents for American Dynamics AD2083-02C

  • Page 1 Installation and Operation Instructions The 2083/02 Code Translator is an interface unit used with American Dynamics Switching Systems. The unit translates codes which then enable the use of American Dynamics equipment with that of Sensormatic Speed Domes and Mini Domes.
  • Page 2 This software/firmware is confidential to and is copyrighted by SENSORMATIC ELECTRONICS CORPORATION. It is not to be copied or disclosed in any manner without the express written consent of SENSORMATIC. The software is furnished to the purchaser under a license for use on a single system. NOTE: Information furnished by SENSORMATIC is believed to be accurate and reliable.
  • Page 3 The installation of this product should be made by qualified service personnel and should conform to all local codes. CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVERS (OR BACK) . NO USER-SERVICEABLE PARTS INSIDE.
  • Page 5: Table Of Contents

    Table of Contents Product Description ...1 Installation ...1 Setup ...2 Connections ...3 Operation ...4 Typical Connections...Appendix...
  • Page 7: Product Description

    PRODUCT DESCRIPTION The 2083/02 Code Translator is used as an interface to American Dynamics switching systems. The 2083/02 allows for the retrofit or new installation of American Dynamics switchers using RS-422 transmission systems and non-AD receivers. This unit only interfaces with Sensormatic Speed Domes and Mini Domes.
  • Page 8: Setup

    SETUP SETUP Camera Block Assignments Four 8-position DIP switches ( S1, S2, S3, and S4) are located on the rear panel of the unit, as shown in Figure 1, page 1. The settings of these switches determine the cameras associated with the connectors in each of four selective groups.
  • Page 9: Connections

    CONNECTIONS Sensormatic Interface Connectors Eight 12-pin connectors on the rear of the 2083/02 Code Translator panel are used for transmitting and receiving codes with Sensormatic domes and J-boxes. The transmit (T) and receive (R) signal positions are labeled on each connector. Each connector is supplied with a mating screw terminal connector (see Figure 4).
  • Page 10: Operation

    Dynamics Start Alarm and Stop Alarm commands are transmitted via the RS232 output port. The alarm contact number is the American Dynamics real camera address. When an alarm is received, an internal relay closes and the green alarm LED illuminates. The alarm reading is an asynchronous operation, working on a first-in first-out basis.
  • Page 11 Table 5 - Sensormatic Dome Commands Dome Function Set Preset 1 - 16 Call Preset 1 - 16 Reset Iris Enter V-Phase Adjust Mode Exit V-Phase Adjust Mode Reset Dome Set Switch 1 Normal Closed Set Switch 1 Normal Open Set Switch 2 Normal Closed Set Switch 2 Normal Open Set Switch 3 Normal Closed...
  • Page 13 APPENDIX...
  • Page 15 ABCD ABCD POWER ALARM ABCD CODE ABCD NOTE: MAX. DISTANCE BETWEEN TERMINAL BOX AND 1995 CONNECTOR IS 1000' (330m), USING COMPUTER GRADE CABLE 18 AWG 1995 RS232 Ports 3-10: 1 1 1 1 2 2 2 2 3 3 3 3 4 4 4 4 5 5 5 5 Pin 3 - XMIT Pin 4 - RCD...
  • Page 16 ABCD ABCD POWER ALARM ABCD CODE ABCD 4 4 4 4 (RCD) 3 3 3 3 5 5 5 5 6 6 6 6 GREEN (XMIT) 7 7 7 7 2 2 2 2 8 8 8 8 1 1 1 1 H H H H P P P P 0 0 0 0 0 0 0 0 4 4 4 4 7 7 7 7 T T T T E E E E R R R R M M M M I I I I N N N N A A A A L L L L B B B B O O O O X X X X J J J J J J J J 0 0 0 0 0 0 0 0 0 0 0 0 7 7 7 7...
  • Page 17 ABCD ABCD POWER ALARM ABCD CODE ABCD NOTES: 1. MAX. DISTANCE BETWEEN TERMINAL BOXES IS 1000' (330m) USING COMPUTER GRADE CABLE 18 AWG 2. IF LESS THAN 7 FEET, JJ0007 CABLE MAY BE RUN DIRECTLY WITHOUT TERMINAL BOXES (RCD) GREEN (XMIT) 4 4 4 4 5 5 5 5...
  • Page 18 ABCD ABCD POWER ALARM ABCD CODE ABCD NOTES: 1. MAX. DISTANCE BETWEEN TERMINAL BOXES IS 1000' (330m) USING COMPUTER GRADE CABLE 18 AWG 2. IF LESS THAN 7 FEET, JJ0007 CABLE MAY BE RUN DIRECTLY WITHOUT TERMINAL BOXES GREEN (XMIT) (RCD) 4 4 4 4 5 5 5 5...
  • Page 19 Declaration of Conformity Manufacturer: Sensormatic CCTV Systems Division Manufacturer’s Address: Sensormatic CCTV Systems Division 1 Blue Hill Plaza Pearl River, New York, 10965 USA Sensormatic Electronics Corporation State Rd. 110 Km 5.8 Poblado San Antonio Aguadilla P.R. 00690 Declares, that the product(s) listed below: Name/Type: Model Number: complies with the EMC Standards EN55022 (Class B), EN50082-1, and also complies with the...
  • Page 20 Dimensions: 3.5" H x 17" W x 7.75" D (89 x 432 x 197 mm) 8000-0926-01 February, 1997 120 VAC, 50/60 Hz, 8 W 230 VAC, 50/60 Hz, 100 mA An American Dynamics Product Designed and built by Sensormatic CCTV Systems Division One Blue Hill Plaza Pearl River, New York, 10965...