Model 1641 Series M-2, S-2 Economical Receivers with Modular Code Board Installation and Operating Instructions This manual describes the installation and operating procedures for the 1641 Series (M-2, S-2) Single-Channel Receiver. Receivers are designed as the remote control device for operation of a motorized camera Pan/Tilt unit and a motorized camera lens unit.
Page 2
The software/firmware furnished with this equipment is confidential to and is copyrighted by SENSORMATIC ELECTRONICS CORPORATION. It is not to be copied or disclosed in any manner without the express written consent of SENSORMATIC. The software/firmware is furnished to the purchaser under a license for use on a single system. Information furnished by SENSORMATIC is believed to be accurate and reliable.
Page 3
The installation of this product should be made by qualified service personnel and should conform to all local codes. CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVERS (OR BACK) . NO USER-SERVICEABLE PARTS INSIDE.
DESCRIPTION The 1641 Series Receivers are used with Matrix Switching Systems to control pan, tilt, zoom, focus, iris, and auxiliary functions at a camera site. These Receivers are classified as a single-channel type since the unit controls only one camera at a site.
When controlled by a Matrix Switching System, the 1641 Series Receiver can be programmed for 71 preset scenes for that camera. (Note: This differs from the American Dynamics' standard of 72 presets per camera.) Refer to the installation and operation manuals for the particular Matrix Switching System for programming procedures.
INSTALLATION This installation should be made by a qualified service person and should conform to all local codes. Safeguards must be taken to avoid unintentional operation by employees, janitors, and cleaners working about the premises, by falling objects, by customers, by building vibration, and by similar causes. Preparation There are many switches that must be set up before operation of this product, as described in SETUP, pages 4 and 5.
SETUP SETUP Camera Number Setup For 1641M and 1641S models: A 10-position DIP switch labeled “CAMERA ID” is used to associate a specific camera number with the Receiver for individual control by the Matrix Switching System. This switch, labeled S10 on the main PCB, is located on the side panel of the 1641 Receiver, near the Pan/Tilt/Lens cable and the LENS ADJ control (see Figure 1, page 1).
Local Test Mode Local Test Mode provides the ability to control a 1641 Receiver without a code line connected. This capability can be used with any model 1641 Receiver. The Local Test Mode feature is operated as follows, using the internal rotary switches S9 and S11, and internal button switch S8.
SETUP 1641M Connector and Switch Locations Figure 4 shows the PCB layout for the 1641M type (AD Manchester Control Code) units. Camera ID Lens Switches Adjust ON 1 Control Code Receiver Module PCB Code Terminal Connector Pan/Tilt and Lens Connector J6 on Receiver Module PCB Pin 1...
1641S Connector and Switch Locations Figure 5 shows the PCB layout for the 1641S type (RS-232) units. Camera ID Lens Switches Adjust ON 1 ON 1 ON 1 RS-232 Receiver Module RS-232 Connector Pan/Tilt and Lens Connector Pin 1 Auxiliary and Preposition Figure 5 - 1641S Connector and Switch Locations Power Cord Pin 1...
CONNECTIONS CONNECTIONS Code Line Connections for AD Manchester Control Code (1641M Series) The 1641M code line connector (J1) is a 3-position terminal, labeled “W”, “S”, and “B” on the side panel of the unit (see Figure 1, page 1, and Figure 4, page 6). A mating 3-position screw-terminal plug is supplied.
For proper RS-232 communications, the EIA Standard DTE (Data Terminal Equipment) pin designations of each piece of equipment must be observed. All American Dynamics equipment, including the 1641S, are configured for DTE operation. For DTE/DTE connection to the 1641S Receiver: 1.
CONNECTIONS Pan/Tilt and Lens Cable The connection to a Pan/Tilt unit and a motorized camera lens is with a 12-pin connector. This connector, labeled J20 on the main PCB, is located on the side of the Receiver near the power cord (see Figures 4, 5, and 6, pages 6, 7, and 8). A mating 12-position screw-terminal connector plug is provided.
Preposition and Auxiliary Cable The connection to Pan/Tilt preposition servos and auxiliary equipment is with a 14-pin connector. This connector, labeled J21 on the main PCB, is located on the side of the unit opposite the power cord (see Figures 4, 5, and 6, pages 6, 7, and 8). A mating 14-position screw-terminal connector plug is provided.
OPERATION OPERATION Powering Up The 1641 Receiver has a pendant cord for use with a standard electrical outlet. The power required for each model is inidicated on the Specifications page at the back of this manual. Model ADS1641M-2F-1 is considered to be Class III equipment as defined in EN60950.
Page 31
CAMERAS W S B TYPICAL SYSTEM CONNECTIONS (AD Manchester Control Code Connection) MAXIMUM DISTANCE between 1641 and 2150 is 5000 Ft, using shielded, 18 AWG cable 2150 Controller to 1641M ALARMS RELAY CODE BWS BWS BWS BWS MONITORS 120V 60Hz KEYBOARDS RS232 PORTS 2150...
Page 32
DATA LINE SELECT CODE ABCDEF B W S B W S B W S B W S ABCDEF B W S B W S B W S B W S ABCDEF B W S B W S B W S B W S ABCDEF B W S B W S B W S B W S B W S...
Page 33
DATA LINE SELECT CODE ABCDEF B W S B W S B W S B W S ABCDEF B W S B W S B W S B W S ABCDEF B W S B W S B W S B W S ABCDEF B W S B W S B W S B W S JJ0007 Cable...
Page 34
1676 Keyboard to 1641S (RS-232 Connection) JJ0007 Cable HP0047 TERMINAL BOX BROWN (GRD) GREEN (XMIT) MAXIMUM DISTANCE BETWEEN 1641 AND 1676 IS 1000 FT, USING SHIELDED, 18 AWG CABLE CABLE SHIELD CHASSIS GROUND CONNECT SHIELD WIRE TO CHASSIS GROUND WITH SHORTEST POSSIBLE WIRE LENGTH. TIGHTEN GROUND SCREW FIRMLY TYPICAL SYSTEM CONNECTIONS 1676...
DECLARATION OF CONFORMITY According to ISO/IEC Guide 22 and EN45014 Manufacturer’s Name: Sensormatic Electronics Corporation Manufacturer’s Address: 1 Blue Hill Plaza Floor Pearl River, New York, 10965 USA Declares, that the products listed below: Name/Type: Model Numbers: comply with all applicable directives as demonstrated by conformance to the following Product Specifications: Safety: EN 60950: 1992 EMC:...
Page 36
SPECIFICATIONS: Model Number Control Interface AD1641M-2 AD Manchester AD1641M-2F AD Manchester AD1641M-2F-1 AD Manchester AD1641M-2X AD Manchester AD1641S-2 RS-232 AD1641S-2F RS-232 AD1641S-2X RS-232 Aux Relay Contacts: 1 Amp @ 24 VAC or 30 VAC Mounting: Surface or Rack Mount Dimensions: Indoor: 7.5”...