PUBLICATION DATE: April 11, 2000 Copyright 1997 by Racal Instruments, Inc. Printed in the United States of America. All rights reserved. This book or parts thereof may not be reproduced in any form without written permission of the publisher.
Page 3
Authorization is required from Racal Instruments before you send us your product for service or calibration. Call your nearest Racal Instruments support facility. A list is located on the last page of this manual. If you are unsure where to call, contact Racal Instruments, Inc. Customer Support Department in Irvine, California, USA at...
Page 4
FOR YOUR SAFETY Before undertaking any troubleshooting, maintenance or exploratory procedure, read carefully the WARNINGS and CAUTION notices. This equipment contains voltage hazardous to human life and safety, and is capable of inflicting personal injury. If this instrument is to be powered from the AC line (mains) through an autotransformer, ensure the common connector is connected to the neutral (earth pole) of the power supply.
Page 5
This page was left intentionally blank. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 6
1260-01S Smart Card. If you are using the newer 1260-01T Smart Card, the commands will NOT work as shown. Consult the 1260-01T Manual for a description of the commands that may be used with the 1260-01T Smart Card. The channel numbers described in this manual are valid for the 1260-01T. The channel numbers continue to be used for the 1260-01T.
Page 7
Control Information for the 1260-36 This card has a unique control scheme that is NOT shared by any other 1260 series relay module. This card comprises 12 1x8 MUXes. There is a total of 6 control registers on the module. Each byte controls 2 1x8 MUXes.
Page 8
EVEN MUX Select Patterns Hex Pattern Binary Pattern Channel Closed x0xx x000 None (Control Bit = 0) x0xx x001 None (Control Bit = 0) x0xx x010 None (Control Bit = 0) x0xx x011 None (Control Bit = 0) x0xx x100 None (Control Bit = 0) x0xx x101 None (Control Bit = 0)
Page 9
0xC0B, 0xC6 ); The 1260-36 is the only 1260 Series Module where the data read back from the control register is NOT inverted. If the value C6 is written to a control register, the value read back will be C6.
User Manual 1260-36 Chapter 1 MODULE SPECIFICATION The 1260-36 FET. Multiplexer/Scanner Module is a VXIbus switch 1260-36 Module module containing twelve 1 x 8 multiplexers. It has the capability of Specification being configured as six 1 x 16 mutilplexers, four 1 x 24 multiplexers, three 1 x 32 multiplexers, two 1 x 48 multiplexers, or one 1 x 96 multiplexer.
User Manual 1260-36 Switch Configuration Break-Before-Make Action Specifications Analog Signal Range -15V to +15V DC to 250 kHz -10V to +10V to 400 kHz -5V to +5V to 2 MHz ± 35 V peak, continuously Overvoltage Protection Nominal 900kΩ ±15%...
Reship in either the original or a new shipping carton. Installation of the Option 01 to the 1260-36 is described in the Option 01 Installation Section of the 1260 Series VXIbus Switching Cards Installation Manual.
Three I x 32 multiplexer/scanners Two I x 48 multiplexer/scanners One 1 x 96 multiplexer/scanners The 1260-36 is shipped from the factory in the 1 x 96 multiplexer configuration. Table 2-I gives information necessary to configure the module into other possible configurations.
User Manual 1260-36 Chapter 3 MODULE SPECIFIC SYNTAX The Module Specific Syntax for the 1260-36 is required in the use 1260-36 Module of the OPEN and CLOSE commands. It also appears in data Specific Syntax output by the Master in response the PDATAOUT and PSETUP commands.
User Manual 1260-36 Chapter 5 PARTS LIST FS930194 Final Assembly, 1260-36................5-3 FS930100 Shipping Kit, 1260-36................. 5-3 Parts List 5-1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 57
User Manual 1260-36 This page was left intentionally blank. Parts List 5-2 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 58
User Manual 1260-36 Parts List 5-3 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 59
User Manual 1260-36 Parts List 5-4 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 60
User Manual 1260-36 Parts List 5-5 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 61
User Manual 1260-36 This page was left intentionally blank. Parts List 5-6 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
User Manual 1260-36 Chapter 6 OPTIONAL HARNESS ASSEMBLIES The following harness assemblies are used to connect Racal Instruments Model 1260-36 to Freedom Series Test Receiver Interfaces. Each harness documentation consists of an assembly drawing, parts list, system wire list and wire list.
Page 63
User Manual 1260-36 This page was left intentionally blank. Optional Harness Assemblies 6-2 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
For worldwide support and the office closes to your facility, refer to the Support Offices section on the following page. Use the original packing material when returning the 1260-36 to Reshipment Racal Instruments for calibration or servicing. The original shipping...