Troubleshooting; Hydromassage Does Not Start; The Hydromassage Stops Of Its Own Accord; The "Strength" Of The Hydromassage Has Got Weaker - Jacuzzi muse Use & Maintenance

Hide thumbs Also See for muse:
Table of Contents

Advertisement

Available languages

Available languages

Troubleshooting...

Hydromassage
does not start
P1
P2
;
;
The hydromassage stops
of its own accord
In addition to the faults listed in the
"hydromassage does not start", sec-
tion, refer to the below described
(*) the code does not
appear when the remote
control is in stand-by
The "strength" of the hydromas-
sage has got weaker; not many
air bubbles come out of the
larger hydromassage outlets
W
e always recommend carefully reading the manual before using your tub; in the in-
stance that there is an issue, refer to the following guide.
Some operation faults are presented on the J.touch remote control display with codes.
lack of electric energy
command not accepted
insufficient water level
L1
possible distributor fault
P3
possible electrical box fault
EI
lack of electric energy
the selected hydromassage pro-
gramme is finished (each programme
has its own duration, after which time,
the hydromassage stops on its own)
insufficient water level
*
L1
the outlet nozzles are closed
poor hydromassage intensity
obstructed air outlets and/or hydro-
massage
46
- check that the main switch is not off and/
or that the system is not faulty (contact your
trusted electrician)
- try to keep the key on the remote control held
down again (also follow the instructions in the
relative chapters)
- add water to the level where, once immersed,
it covers the highest nozzles on the backrest
and once again, hold down the key
- switch off the tub and contact a Jacuzzi® Sup-
port Centre
- switch off the tub and contact a Jacuzzi® Sup-
port Centre
- check that the main switch is not off and/
or that the system is not faulty (contact your
trusted electrician)
- where desired, re-start the hydromassage (re-
fer to the relative chapter)
- add water within about 5 minutes from the
appearance of the warning (the function will
resume automatically); where this is not the
case, the function will be definitively reset
- open the nozzles (refer to Chapter "prelimi-
nary operations - some recommendations")
- use "+" on the remote control, as indicated in
the relative chapters.
- clean the outlets as described in the Chap-
ter "Maintenance"; where this is not sufficient,
contact a Jacuzzi® Support Centre.