61000-4-16
61000-4-17
IEC 60255-5
a
Siemens specified severity level.
IEEE 1613 EMC Immunity Type Tests
Note
The RUGGEDCOM RS416PF meets Class 2 requirements for an all-fiber configuration
and Class 1 requirements for copper ports.
Fast Transient
Dielectric Strength
RUGGEDCOM RS416PF
Installation Manual, 04/2021, C79000-G8976-1355-04
Test
IEC
Mains Frequency Voltage
IEC
Ripple on DC Power Supply
Dielectric Strength
HV Impulse
Description
ESD
Radiated RFI
Oscillatory
HV Impulse
6.2 EMC and Environmental Type Tests
Description
AC Power
ports
Signal ports
DC Power
ports
DC Power
ports
Signal ports
DC Power
ports
AC Power
ports
Signal ports
DC Power
ports
AC Power
ports
Enclosure Contact
Enclosure Air
Enclosure ports
Signal ports
DC Power ports
AC Power ports
Earth ground ports
Signal ports
DC Power ports
AC Power ports
Signal ports
DC Power ports
AC Power ports
Signal ports
Test Levels
2.5 kV common, 1 kV
differential mode @ 1 MHz
30 V Continuous,
300 V for 1 s
30 V Continuous,
300 V for 1 s
± 15%
2 kVAC  (Fail-
Safe Relay output)
1.5 kV
2 kV
5 kV  (Fail-Safe
Relay Output)
5 kV
5 kV
Test Levels
± 8 kV
± 15 kV
35 V/m
± 4 kV @ 2.5 kHz
± 4 kV
± 4 kV
± 4 kV
2.5 kV common mode @ 1MHz
2.5 kV common and
differential mode @ 1MHz
2.5 kV common and
differential mode @ 1MHz
5 kV (Failsafe Relay)
5 kV
5 kV
2 kVAC (Failsafe Relay)
Certification
Severity
Levels
3
4
4
4
 
 
 
 
 
 
45