TCS FBO1100-0400 Product Information page 14

Interface for tk systems
Table of Contents

Advertisement

command
parameter
Sensor AS address (10 ... 63)
3 3
X X
3 4
no parameter!
Dialing register
3 5
X X
Project number (0000 ... 9999)
3 6
X X X X
0=OFF 1=ON
3 7
X
0= ignore 1= door call 2= floor call
3 8
X
0=no PIN 1=input PIN
2=HW-Reset
3 9
X
0=short 1=long
4 0
X
0=16bit, short 1=32 bit, long
4 1
X
0=short 1...9 (* 30s = 30...270 s)
4 2
X
0=commands 1directly to AS(2)
4 3
X
0=normal 1=blank
4 4
X
0=no acous. note 1=note
4 5
X
0=4 dialing reg. 1=16 dialing reg.
2=32 dialing reg. 3=64 dialing reg.
4 6
X
0=deactivate the numeric mode
1=activate the numeric mode
4 7
X
0=no numeric mode SN
1=numeric mode, train the SN
4 8
X
0=max. 20 Ohm 1=max. 60 Ohm
4 9
X
1) If at command 46, parameter 0=4 dialing register is set, the factory setting automatically changes at command 39 to 1.
A long tone sounds when calling the TKI. Enter 0000 after the tone (see command 10).
aQ entry Pin expected when calling the TKI
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88
FAX: +49 (0) 41 94/ 9 88 129  Mail: hotline@tcsag.de
14
end of
com-
function
mand
*
Enter the AS address to the sensor in case for a voice connec-
tion
Starts the transmission of the TK-Interface internal parameter
block
*
Start of the read-out of the parameter block to the dialing regis-
ter XX
*
Enter the project number with 4 digits
*
Control of the error tone output
*
Setting the function of an internal call to the TK-Interface
*
Activating the function of an input PIN
*
Setting the timeout after the dial
short = 10 s / long = 45 s
*
Setting the door release command
*
Setting the delay time
*
Setting the reaction on the call at the TK-Interface
*
Blank / not change the dial tones
*
Acoustic note "call at the TK-Interface" at the incoming call
*
Number of dialing register / set the type of the TK-Interface
*
Activate / deactivate the numeric mode
*
Activate the training of the serial number (SN) to the numeric
mode
*
The max. permitted loop resistance between TK-Interface and
power supply and control unit
(1 not possible with BVS20)
factory setting
of the parame-
ter
Subject to technical changes.
PI_FBO1100_uk 1A
04/2013
6 4
no voice connection
none
none
0 0 0 0
1
2
1)
0
1
0
0
0
0
1
1
0
0
0